13.4
Programming the instruments
The operating parameters can be modified using the front keypad, and are divided into
two families: frequent use parameters (type "F") and configuration parameters (type
"C"). Access to the configuration parameters is protected by a password that prevents
unwanted modifications or access by unauthorised persons.
13.4.1 How to access type "F" parameters
Press
for more than 5 seconds (if an alarm is active, the buzzer is muted first of
all), the display shows the code of the first modifiable type "F" parameter.
13.4.2 How to access type "C" parameters
1) Press
ber "00", representing the password prompt;
2) Press
access to the parameters);
3) Confirm by pressing
"C" parameter.
13.4.3 Modifying the parameters
After having displayed the parameter, either type "C" or type "F", proceed as follows:
1) Press
icon appears on the display representing the category the parameter belongs to.
2) Alternatively, press
of parameters to be modified.
3) Scroll the menu with the
various categories of parameters (see the "Summary of operating parameters"),
accompanied by the display of the corresponding icon (if present).
4) When having reached the desired category, press
parameter in the category (if there are no visible parameters in the selected category,
pressing
5) At this stage, continue to scroll the parameters, or return to the Categories menu by
pressing
6) Press
7) Increase or decrease the value using the
8) Press
ter code.
9) Repeat the operations from point 1 or point 2.
10) If the parameter has sub-parameters, press
11) Press
12) Press
13) Increase or decrease the value using the
14) Press
parameter code.
15) Press
Code CT55900010
and
together for more than 5 seconds; the display will show the num-
or
until displaying the number "22" (the code of the password allows
; the display will show the code of the first modificable type
or
until reaching the parameter to be modified. When scrolling, an
to display a menu that is used to quickly access the "group"
will have no effect).
.
to display the value associated with the parameter.
to temporarily save the new value and return to the display of the parame-
or
to display all the sub-parameters.
to display the associated value.
to temporarily save the new value and return to the display of the sub-
to return to the display of the parent parameter.
and
buttons; the display shows the codes of the
or
or
English - 27
to move directly to the first
buttons respectively.
to display the first sub-parameter.
buttons respectively.
Rev. 03 - 07/'06