Declaration in accordance with Directives 2004/108/CE (EMC); 2006/95/CE (LVD)
The Manufacturer:
AUTOMATISMI BENINCÀ SPA
Address:
Via Capitello, 45 - 36066 Sandrigo (VI) - Italy
Declares that the product:
Control box for 1 motor, for LOGICA tilt-up doors - CP.ZED230E
conforms with the requirements of the following EU Directives:
• DIRECTIVE 2004/108/CE OF THE EUROPEAN PARLIAMENT AND COUNCIL, 15 December 2004, in relation
to the harmonisation of the legislation of member states regarding electromagnetic compatibility, in abrogation of Directive
89/336/CEE, per the following harmonised standards:
EN 61000-6-2:2005, EN 61000-6-3:2007.
• DIRECTIVE 2006/95/CE OF THE EUROPEAN PARLIAMENT AND COUNCIL, 12 December 2006, in relation to
the harmonisation of the legislation of member states regarding electrical material intended to be used within certain voltage
ranges, per the following harmonised standards:
EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + A13:2008; EN 60335-1-103:2003.
as applicable:
• DIRECTIVE 1999/5/CE OF THE EUROPEAN PARLIAMENT AND COUNCIL, 9 March 1999 in relation to radio
equipment and telecommunications terminals and the mutual recognition of their conformity, per the following harmonised
standards:
ETSI EN 301 489-3 V1.4.1 (2002) + ETSI EN 301 489-1 V1.4.1 (2002) + ETSI EN 300 220-3 V1.1.1 (2000) + EN 60950-1
(2001)
Benincà Luigi, Legal representative.
Sandrigo, 08/07/2008.
The electronic control unit Logica230 can be used to control 1 or 2 motors with a power not exceeding 300W+300W.
IMPORTANT: Should two motors be used, connect the limit switches of one single motor to the control unit.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be detached, or adequately insulated by an additional insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that setting of the Dip-Switches are the required ones.
f) Normally Closed inputs which are not in use should be short-circuited 230VAC – keep to phase/neutral).
Terminal No. Function
1-2
Power supply
3-4
Flashing light
4-5
Light, Motor
6-7-8
Motor 1/2
9
COM
10
SWO
11
SWC
12
STOP
13
PHOT
14
OPEN
CE Declaration of Conformity
Logica230 Control unit
GENERAL WARNINGS
INPUT/OUTPUT FUNCTIONS
Logica230 Control Unit
Description
Input, 230VAC 50Hz (1-Phase/2-Neutral)
Connection of flashing light, 230Vac 40W max.
Connection to the courtesy light
Connection to motor 1/2 : (6-speed/7-Com/8-speed)
Should 2 motors be used, connect the second motor in parallel.
Common for limit switch and all control inputs.
Input, OPEN limit switch (N.C. contact)
Input, CLOSE limit switch (N.C. contact)
Input, STOP push button (N.C. contact)
Input, connection to safety devices, N.C. contact
(e.g. Photocells)
Input, OPEN push button (N.O. contact)
7