11.1.3. Electricity:
WARNING:
ALLWAYS CONNECT ELECTRICITY
LAST.
Connect the plug to the wall socket, make sure the
plug is properly connected.
NOTE:
Red LED will illuminate.
If not, press red re-set button.
12. Preparing the unit
NOTE:
Before use, the unit must be filled with
water.
NOTE:
Make sure the power supply to the unit is
not connected.
Turn on the water supply to the unit.
Open the Ball walve on the outlet hose until no air or
dirt comes out.The unit is now ready for use, recon-
nect the power supply.
Bleed the piping system.
13. Testing the unit
1. Make sure water, product and electricity are con-
nected to the unit.
2. Pull the outlet to the desired length.
3. Connect the desired nozzle foam (white), rinse
nozzle (blue) or sanitize(red).
4. Connecting the nozzle is done by pulling back
the quick connector/ coupler (Fig. 11). Connect
the nozzle by pushing the nozzle into opening in
the quick connector.
NOTE:
Make sure the nozzle is "clicked" properly
in to the coupling, you will hear a small
click when the nozzle slips in to place.
13.1. Testing the Rinse function:
Hold the ball valve / pistol over sink for testing.
1. Turn the selector knob on the unit to rinse posi-
tion.
2. Connect the rinse wand to the ball valve / pistol.
3. Open the ball valve / pistol and the pump will
start, it may take several seconds for the outlet
hose to be filled completely with water.
4. The unit is now rinsing.
5. Close the ball valve / pistol to stop rinsing. The
unit will automatically stop a few seconds after
the ball valve / pistol is closed.
13.2. Testing the Foam function:
Hold the ball valve / pistol over sink for testing.
1. Turn the selector knob on the unit to foam posi-
tion.
2. Connect the foam nozzle to the ball valve / pistol.
3. Open the ball valve / pistol. First the pump and
then the compressor will start, it will take about
10-15 seconds for the outlet hose to be filled
completely with foam.
4. The unit is now foaming.
5. Close the ball valve / pistol to stop foaming, the
unit will automatically stop, it can take up to 10 -
20 seconds after the ball valve / pistol is closed
before the unit stops.
• We recommend maximum 20 min. continuous
operation of the compressor (foam mode).
11