Opening time regulation
You can vary the time of the opening manoeuvre with the potentiometer (T open)
(clockwise is more time).
We recommend that this time is a little more than the time needed to open the door
completely.
In case the actuator has limit switches, the opening time will be used as security stop when
these switches fail to work.
Closing time regulation
You can vary the time of the closing manoeuvre with the potentiometer (T closure)
(clockwise is more time).
We recommend that this time is a little more than the time needed to close the door
completely.
In case the actuator has limit switches, the closing time will be used as security stop when
these switches fail to work.
Waiting time regulation
You can vary the waiting time with the potentiometer (T waiting) (clockwise is more time).
Once this time has passed, the door will close automatically.
1. Automatic/semi-automatic function
1
2
3
ON
OFF
door will stop and inverts the manoeuvre during same time applied for closing the door.
1
2
3
ON
OFF
When the door is closing and you push the key, the remote control or you activate any secu-
rity element (photocell, magnetic strip,...), the door will stop and inverts the manoeuvre
during same time applied for closing the door.
FUNCTIONS' DESCRIPTION
1.1. Semi-automatic function (closing manoeuvre by pushing a button)
Pushing the key or the remote control the door will open and stay
open for an undefined time.
To close the door you have to push again.
When the door is closing and you push the key, the remote control or
you activate any security element (photocell, magnetic strip,...), the
risation)
Pushing the key or the remote control the door will open and stays
open until the programmed waiting time (T waiting) has passed.
Once this time has passed, the door will close if the security elements
allow so.
1.2. Automatic function (closure by tempo-
23