PROGRAMMING AND STARTUP
6

SELECTION OF CONTROL BOARD FUNCTIONS AND MODES (SW2)

Using SW2, choose the required options (see "SW2 functions" on page 47).
7

POTENTIOMETER ADJUSTMENT

8

START UP

Final checks
Following installation and programming, start up the
operators and check the devices installed:
1 Check the correct working of the key devices (push
button, key switch and transmitter).
See "Functioning modes" on page 41.
2 Check the correct operation of the safety devices
(photocells or mechanical strips).
See "Detection by safety device (photocell or
mechanical strip)" on page 41.
3 If everything is correct, close the control board
cover.
If the system does not work correctly, find out
why and put it right (see section "Failure
diagnosis" on page 53).
52
Installation Manual
FCA2 COM FCC2
SCA
P1 P2 P3
P4 P5 P6
P15 P14 P16
P7 P8
P11 P12
ST1
ST2
FT2
FCA1
FCC1
STOP
LOCK
FT1
P167M
Regulation of lapse time between the leaves in
closing (T.D.)
Regulate the time which must pass between the start of
the closing of the leaves. The opening lapse time is not
adjustable.
When using a single operator, set T.D. to the
minimum.
Regulation of garage light time (T.LG)
If the garage lighting circuit has been connected to the
control board, regulate the time which the lamps shall
remain on using T.LG.
Minimum value: 3 seconds; maximum value: 120
seconds.
Setting standby time (T.E.)
If automatic operation mode has been programmed
(DIP4=ON), adjust T.E. to adjust standby time with the
gate open (before automatic closing begins).
Minimum value: 3 seconds; maximum value: 60
P22
seconds.
24Va
Torque adjustment (P.M.)
Correct
torque
importance to prevent injury and damage.
Increased torque produces a more violent
impact.
• Hydraulic operators: set P.M. at the maximum value.
• Electromechanical operators: set P.M at the
minimum value possible, compatible with the
proper operation of the gate.

User instruction

1 Instruct the user with regards to the use and
maintenance of the installation and provide him/her
with the user guide.
2 Signpost
the
automatically and indicating how to operate it
manually.
Where
operation is using the remote control.
adjustment
is
of
gate,
showing
that
it
appropriate,
indicate
vital
opens
that