2. Features and operation

Common Display features & Specification
Display
Display functions
On target indicator
Low Battery indicator
Function icons
Controls - 3 push-buttons
On/off normal mode
On/off inverted mode
Program control
Optical system - Laser
Optical range
Angle of operation
Light source
Measurement modes
Optical
Via contact adaptor
Count
Measure Time
Speed Capture
feature
Speed range
Optical mode
Contact mode
Linear speeds -
maximum
SKF TMRT 1
Inverting LCD Vertical 5 digit display
180° Inverting
Yes
Yes
Comprehensive selection of ranges shown
in display
Dual action switch (UP ARROW)
Dual action switch (DOWN ARROW)
Selects program mode in conjunction with
Up/Down switches
50 mm - 2 000 mm
+/- 80°
Red Spot Laser Class II
rpm and rps
(also Count and Time interval)
rpm & rps, metres, yards, feet,
per min & per sec
Total revs, metres, feet, yards
Interval in seconds between pulses
(reciprocal rate)
Maximum, minimum or average rate
3 - 99,999 rpm (or eq uivalent in rps)
Max. 15 000 rpm for 10 sec
(or equivalent in rps)
0,30 - 1 500 metres or Yds/min.
(4 500 ft/min) or equivalent in seconds