Erreka IZAR O MAXI VIVO-D102 Manual Del Instalador página 48

Ocultar thumbs Ver también para IZAR O MAXI VIVO-D102:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

STARTING UP AND PROGRAMMING
Radio code programming (only with RSD) and door open/close programming (D1= "P")
O
Before programming the door open/close,
ensure the turning direction of the operator is
correct (see "Prior Conditions Programming
(D1= "C")" on page 47).
The radio code programming described below is
only valid if the RSD plug-in receiver has been
installed. If a different receiver is used, programme
the radio code as described in the corresponding
instructions.
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
P flashing. Press ENTER to confirm. D2 flashes.
D1
D2
D3
P
1
o
2
3
o
Main Functions Programming (D1= "F")
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
F flashing. Press ENTER to confirm. D2 flashes.
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
D1
D2
Parameter
F
1
Functioning mode
2
Standby in automatic mode
3
a. For further details, see "Functioning modes" on page 37.
48
Installation Manual
until D1 shows the letter
V
D4
ç
Total opening radio code
programming
Disabled
ç
Door open/close
programming
until D1 shows the letter
V
until the required D2
V
D3
0
a
0
1
0
5:
...
3 Press the buttons ^ and
parameter appears (see chart). Press ENTER to
confirm. D3 and D4 flash.
4.a Radio code programming (D2=1):
• Press the transmitter button. If the code is
correctly programmed, D3-D4 stop flashing
(remain static).
4.b Door open/close programming (D2=3):
• Press ENTER. D3-D4 stop flashing (remaining
static)
• Press the total opening button. D3-D4 flash
again whilst the programming of the operations
is done automatically. The door carries out the
following movements:
– Reset (close position search)
– Total opening
– Total close
• When programming is finished, D3-D4 stop
flashing (remaining static).
5 Press ESC to return to the previous display.
4 Press the buttons ^ and
D4 value appears (see chart). Press ENTER to
confirm.
5 Press ESC to return to the previous display.
For operation different to the options defined in this
menu, access the advanced functions menu (see
"Advanced Functions Programming (D1= "A")" on
page 49).
Pre-
D4
determined
Options or values
option
1
Automatic
2
x
Step-by-step
5
x
15 seconds
0
9
59
...
Disabled
until the required D2
V
until the required D3 and
V
2: 5
= 59 sec;
= 2 min. 50 sec., etc

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Izar o maxi vivo-d102m

Tabla de contenido