INSTALLATION INSTRUCTIONS
Electric cable connections (fig. N)
In order to connect the electrical cables
to the control unit inside the mecha-
nism(4) you must proceed as follows:
- remove the 4 screws from the front
panel (4a)
- connect the cables to their sites by
inserting their connectors, which must
be inserted without forcing them
- connect the plug to the mains and
check that the synoptic panel is
functioning properly by following
the instructions attached to it
- reassemble the front panel being
careful not to bend or crush the
synoptic panel cable, then proceed with
the installation of the fireplace.
- these procedures must meet installation
standards and be built to the highest
professional standards.
12
rete 230 Vac
- ensure that the electrical wires do not
have any areas of contact with the
prefabricated appliance and the smoke
channel
- no parts of the electrical equipment
supplied with the fireplace must be
tampered with
- the electrical components are always
live, prior to any work, unplug the
equipment or turn off the general
electrical panel for the housing.
Connecting forced ventilation
(fig. N-O)
- extend the lead with the plug all the
way to the socket
- mount the covering all the way up to
the beam, and then build the mantel
with plasterboard panels as follows:
22a
14
6a
13
fig. N
• the first side panel
• front Panel
- secure outlets (22) in the top part of
the frames after making a hole of
37x10, 5 cm
- secure the sensor (14) inside the hole
(22a) of the outlet (B1 or B3)
- check that the wire of the sensor does
not interfere with the movement of
the retractable door
• the second side panel
- finish the mantel by mounting the
second side panel
- and apply the snap on grilles to the
outlets from the outside
- when the work is complete, plug in
the plug to the 230 Vac power supply
sensor
14
230 Vac
power supply
fan
12
electrical control
13
unit
19
outlet
22
fig. O