CHIMNEY FLUES AND CHIMNEYPOT
The thermo replace smoke outlet has a circular crosssection
so that stainless steel pipes can be used. If the chimney ue
inlet is not vertically above the thermo replace, the connection
from the replace to the ue must not have a narrowing
section or inclinations greater than 45° ( g. 1-2-3-4).
The replace unit must not be connected to a shared ue.
The fume section must be inspectable and installed in such a
way that it can be cleaned (use inspectable TEEs).
If the chimney ue is not brand new or too big, it is recommen-
ded to t in stainless tubes of an appropriate diameter and with
suitable insulation.
If the chimney ue is installed outside, it is recommended to
use an insulated, double walled, stainless steel ue.
The characteristics of the construction must be suitable to
withstand a smoke temperature of at least 450° C, with parti-
cular reference to the mechanical resistance, insulation and the
gas tight sealing.
The ue must be certi ed under EN 1856.
The junction of the steel ue inlet and the smoke outlet of the
replace must be sealed with high temperature mastic.
Have quali ed personnel clean the ue once a year.
max.45°
inspection
1
2
The fundamental characteristics of the chimneypot are:
- an internal cross-section at the base, which is the same as that
of the chimney ue.
- an outlet cross-section which is no smaller than twice that of
the chimney ue.
NO
- its position must be high enough to catch the wind and avoid
downdraft areas in turbulent wind.
In addition to that mentioned above, please consider the
indications stipulated in UNI 10683/2005 standard, para-
graph 4.2: "connection to the smoke outlet system" and its
subsections.
INSTALLATION COVERING, FIREPLACE
MANTEL
If combining with a pre-fabricated Edilkamin covering, to de -
ne the exact positioning of the thermo replace, it is important
to take the chosen covering model into consideration.
The positioning is implemented according to the model chosen
(refer to the installation instructions found inside the packaging
of each thermo replace covering).
Always ensure the thermo replace is level during the installa-
tion process.
- Drill a hole into the wall or the ooring for the external air
intake and connect the air adjustment mechanism to the hole as
described in the chapter called "external air inlet".
INSTALLATION
45°
NO
45°
3
4
- Use a stainless steel ue to connect the thermo replace to the
chimney ue, adhering with the diameters indicated in the spe-
ci cations table and the guidelines given in the chapter called
"chimney ues".
- Verify that all moving parts function properly before setting
the thermo replace covering in place.
- This system must be tested and ignited for the rst time
before the covering is set in place.
The base of the thermo replace covering must allow the
internal air to be recycled. Therefore, suitable slots or apertures
must be made for the air to pass through. Parts of the thermo
replace covering that are made of marble, stone and bricks
must be mounted with a small gap between them and the re-
place so as to prevent possible breakage due to expansion and
excessive overheating.
Protect wooden parts with reproof materials.
Fireproof parts of the covering (beams or frames) must not be
in contact with the replace unit but must be at least 1-2 cm
away to allow a ow of air that prevents heat accumulation (see
Fig. 1/a).
The housing compartment must be made of masonry or repro-
of materials and must not have combustible elements inside.
The replace mantel can be made of reproof plasterboard
panels or gypsum board and, however, of completely reproof
material. Air should be allowed to ow inside the replace
mantel (through the gap between the door and the beam).
Through convective motion, the air will ow out from the grille
installed at the top, resulting in heat recovery and preventing
excessive overheating (See Fig. 1/a).
The replace mantel must have appropriate openings to carry
out maintenance on the ttings.
In addition to that mentioned above, please consider the in-
dications stipulated in the UNI 10683 standard, paragraphs
4.4 and 4.7: "insulation, nishing, replace covering and
safety recommendations".
Insulating mats must be applied when using an installation
KIT so as to protect it from the heat radiation emitted by
the thermo replace.
Fig. 1/a
- 31
-
Hot air
ow
grille
Mantel
Door slider
guide
Metal mantel
Hood
Wooden
beam
Front part
Air inlet in the
mantel
sliding door