• Clean the hood using a damp cloth
and a neutral liquid detergent.
Controls
Button Function
A
Turns the Motor off.
Enables / Disables Keyboard Lock mode if pressed and held
for 2 seconds.
B
Activates speed one.
Pressing and holding the button for 2 seconds enables the
remote control.
Pressing and holding the button for 2 seconds disables the
remote control.
C
Activates speed two.
D
Activates speed three.
E
Activates Intensive speed. This speed is timed to run for 6 minutes.
At the end of this time the system will automatically return to the
speed set before.
It is disabled by pressing the Button or turning the Motor off.
F
Activates Delay mode, with automatic shutdown of the Motor, the
Fans and the Lighting with a 15' delay.
It is disabled by pressing the button or turning the motor off.
Press and hold the button for approximately 2 seconds, with
all the loads turned off (Motor and Lights), to turn the Activated
Charcoal Filter alarm on.
To turn it off, press and hold the button again for 2 seconds.
G
Press briefly to turn the lighting system on and off at maximum
intensity.
Holding the button down for 2 seconds to switch on the lights at
a intermediate brightness.
H
When the filters alarm is triggered, the alarm can be reset by
pressing and holding this button for approximately 2 seconds, all
leds flash thrice.
Z
Lighting
• For replacement contact technical support ("To pur-
chase contact technical support").
Led
All the Leds light up in cycle.
All Leds flash twice.
All Leds flash once.
The Delay Led lights up.
All Leds flash twice.
All Leds flash once.
When the procedure terminates, the indication shown
previously turns off:
C+H Flashing
Indicates the need to wash the metal grease filters. The
alarm is triggered after the Hood has been in operation for
100 working hours.
D+H Flashing
Indicates the need to change the activated charcoal filters,
and also to wash the metal grease filters. The alarm is
triggered after the Hood has been in operation for 200
working hours.