Descargar Imprimir esta página

Troubleshooting; Technical Specifications - Trilux EOM Serie Manual De Instrucciones Y De Instalación

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21

Troubleshooting

The luminaire is not functioning.
No mains voltage.
4 Check whether mains voltage is applied with a voltage tester.
The lamps are defective.
4 Replace the lamps.
Luminaire has been switched off via the transmitter.
4 Switch on luminaire.
Luminaire responds to button pressing not as expected.
Transmitter has not been taught in.
4 Teach in transmitter.
Master luminaire with integrated radio receiver is too far from
the transmitter.
4 Reduce distance between transmitter and luminaire.
Button on transmitter was pressed too long or too shortly.
4 See the ‚Modify brightness' section.
18

Technical specifications

Power consumption
Load capacity of signal output
lasts
Max. number of wall/hand transmitters
Transmission capacity of wall/hand
transmitters
Switching cycles of wall/hand transmitters
Frequency band
Functional range
Free field:
Halls:
Corridors and hallways:
Rooms with wooden or gypsum plaster walls:
Rooms with brickwork or gas concrete walls:
Rooms with reinforced concrete walls:
max. 1.5 W
max. 15 bal-
per output
30
10 mW
> 50,000
868.3 MHz
approx. 300 m
approx. 100 m
approx. 50 m
approx. 30 m
(max. 7 walls)
approx. 20 m
(max. 3 walls)
approx. 10 m
(max. 1 wall)