If there is molten material between
the pot and the glass, set the hot
plate to maximum power and try to
separate them.
Single Sensor Error :
If any of the sensors is active more
than 10 seconds, this error situation
occurs and error code"F1" is showed.
This error can be related with different
roots. One of them is that there may
be an object (fork, knife...) on the any
of the sensor.
Make sure that there is no any object
on the control unit, hob glass is wiped
with a dry cloth. If error situation
continue after this solution, please
take out plug or switch off fuse switch
for 10 second.
Plural Sensor Error:
If more than 2 sensors are sensed at
same time, this error situation occurs
and error code"F2" is displayed.
Potential root reasons of the
problem :
• There may be an object(pot...) or
water accumulation(overflow liquid
from pot...) that cover more than 2
sensors
• Touch control location may
exposure more heat or steam
(from oven bottom of the hob...)
Please be sure that there is no any
object on the sensors and switched off
all steam and heat sources. Then,hob
glass is wiped with a dry cloth. If error
situation continue after this solution,
please take out plug or switch off fuse
switch for 10 second.
FC Error:
Fc message on the control and the
hot plates switch off: Overheating
in the electronics. Let thestove cool
for a while.