Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
400V/3, which can be switched to 230V/3
(see next point).
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential
safety breaker close to the appliance.
2 - Remove the control panel (B).
3 - Connect the automatic circuit-breaker (A)
to the terminal board (C) of the appliance
as shown in the diagram and in the electrical
The appliance is supplied at an operating voltage
400V/3 (indicated on the sticker applied to the data-
IT
plate); conversion to 230V/3 can be carried out as
described below.
GB
Caution - warning
Before doing any work, cut off the mains elec-
DE
tricity supply.
1 - Remove the control panel (A).
FR
2 - Modify the connections to the heating element
terminals (B) as shown in the electrical system
ES
diagram at the back of the manual.
3 - Replace the control panel (A).
4 - Remove the test voltage indicator sticker from
the dataplate and apply the new one to identify
the voltage being used.
Important
On completion of the operation make sure
that there are no malfunctions.
English
ELECTRICAL CONNECTION
CONVERSION OF ELECTRICITY SUPPLY
A
B
system diagram at the back of the manual.
N.B.: use a cable with at least H05RN-F characteristics.
Important
When connecting, take care to connect the
neutral and earth lines.
4 - Replace the control panel (B) on completion of
the operation.