Access the parameter menu by holding the ENTER button until the rst parameter, appears. Press
the ENTER button (P2) repeatedly to advance through the parameters menu. To change the pa-
rameter press
UP/DOWN (P1)
N.B. any variation in function must be made with the automation closed
FUNCTIONS/VALUES
SENSITIVITY
AUTOMATIC CLOSURE
(seconds)
STEP BY STEP COMMAND
P/P
% DECELERATION
ELECTROBRAKE
MAXIMUM WORKING TIME
EXTENSION
(expressed in seconds)
CONDOMINIUM
(OPEN ONLY)
MOTOR FORCE
CLOSE AFTER TRANSIT
TIMER/MAGNETIC COIL
ON STEP/STEP
SOFT START DELAYED
START TIME
MOTOR TYPE
DEAD MAN
PRE-FLASHING
N.B.:Once the parameters have been displayed, the total manoeuvres counter are shown in two
different screens, where the thousand units are indicated by the lighting up of the point. To reset
this counter, simultaneously press and hold buttons P1 and P2 (ENTER/UP-DOWN) until 0000 is
displayed
N.B. If the point of the LCD on the left lights up, it means that 10,000 manoeuvres have been ex-
ceeded, which must be added to the value shown.
To exit parameter display, press ENTER several times until automatic closure condition is shown
(- - two dashes).
PROGRAMMING FUNCTIONS
Medium
--
High
High
NO
5
Open
By activating the step/step function, you avoid passage of the automa-
Open
Stop
tion in the stop state. The enabled function may be critical for automa-
Close
close
NO
10%
20%
heavy gate is prevented from continuing its movement, due to its iner-
NO
YES
tia, for a few seconds instead of stopping it instantenously following a
90
180
Activate the condominium function so that the rst step/step impulse
NO
YES
100%
10%
20%
Max
Min
When you activate the Close After Transit function with automatic clo-
NO
YES
sure activated, the automation is closed in the shortest time possible
When you activate the function Timer / Magnetic Coil via parameter P
after terminating total opening if step/step contact N.8 is ept closed
the automatic closing time is loc ed so that the gate never closes until
NO
YES
the step/step contact is opened again, if there are several step/step
impulses during the standby time for automatic closing the time will be
When you activate the Soft Start function, during the rst seconds of
NO
YES
movement of the automation the control unit eeps the motor at redu-
--
Type 1
Type 2
When you activate the Man Present function via parameter U, you can
open the automation until step/step contact N.8 is closed and close the
NO
YES
automation until contact PED n.7 is closed when the two contacts are
NO
1sec
2sec
Me-
Obstacle detection activated with L=0 and
dium
Low
Low
10
15
20
25
tions with high inertia.
When the deceleration function is activated in the
last seconds of operation of the automation, the
30%
control unit slows the motors based on the selected
By activating the electrobra e function through the F parameter, a
command or a safety action
Maximum wor ing time extention 90/180 seconds
opens and accepts only re-opening during closing
30%
40%
50%
without waiting for automatic re-closing.
continuously reset
ced speed for a softer start.
Select the desired type of slowdown
released the automation goes to STOP position.
When the pre- ashing function is activated, before
4sec
any movement the asher is activated for the
15
motor with ENCODER sensor
30
40
80
120
%.
60%
70%
80%
90%
selected time