18
Troubleshooting and Actions for Power Atomizer
State
(3)
Pressure
decreases if
the delivery
valve is
opened
(4) Spraying hose vibration
(5) Noise
(6) Liquid leak/oil leak
Nozzle worn out
Nozzle
Too much nozzle spray volume
Power atomizer
Tool small water intake volume
Too long spray hose
Hose
Too thin spray hose
Water leak from hose connection
Air chamber filled with water
Poor pressure control valve motion
Water intake/pressurizing line error
(clogging, looseness)
Nozzle clogged
V pulley fastening bolt loosened
Connection rod bolt, etc. loosened
Bearing broken
Pressure control valve assembly error
Air intake
O-ring damaged
Seal packing damaged
Oil seal damaged
Tightening/assembly error
Cause
Action
Replace
Replace with a proper nozzle
See (1)
Set the proper length
Set the proper thickness
Repair/replace
Supply air
(idling within 1 minute)
Disassemble/adjust
Disassemble/adjust
Clean
Retighten/replace
Retighten
Replace
Adjust
Check
Replace
Replace
Replace
Disassemble/adjust