SMA Solar Technology America LLC
5. Lead a silicone tube over the conductors inside
the Rapid Shutdown Box.
6. Strip off the conductor insulation by 8 mm (0.31 in).
7. In the case of fine stranded wire, provide each conductor with a bootlace ferrule.
8. Connect the conductors to a five-pole plug.
Observe the pin assignment.
9. Place the cable tie onto the silicone tube, tighten
and cut off the projecting end of the cable tie.
This connects the conductors and the silicone
tube together securely.
10. Plug the five-pole plug with the connected
conductors into the upper pin row of the terminal
block RSC.
11. Connect the Rapid Shutdown Boxes together. To do so, connect the incoming conductors to a
plug and plug this into the lower pin row of the connecting terminal block RSC, and always
connect the outgoing conductors to a plug and plug this into the upper pin row of the terminal
block RSC.
12. In the last Rapid Shutdown Box, plug the second
five-pole plug into the lower pin row of the
terminal block RSC and place a jumper wire
between pins 3 and 4. Here, use a jumper wire
that is rated for the maximum system voltages or
insulate the jumper wire using a piece of one of
the supplied silicone tubes.