Descargar Imprimir esta página

Nilfisk IQ 215 Instrucciones De Uso página 7

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
shaking and brushing it.
b) Pre-filter: Remove the main filter as
described earlier, the pre-filter is located
underneath the main filter. The pre-filter
can be washed. Exchange it when the filter
indicator lights up even after cleaning it.
Place the filters with it's stiff side down.
c) HEPA-filter: This filter purifys the
exhaust air from 99,99% of all particles
larger than 0,3 microns. Open the filter
cover as in 7a. Remove the filter cover by
pulling one side of the filter cover
uppward/forward until the filter cover
comes of. Change the HEPA-filter when the
filter indicator lights up after the dust bag
and the other filters has been changed.
Mounting: Push the filter into the cover
as illustrated. Make sure the hooks inside
the cover grasp the edge of the HEPA-filter.
Then press the HEPA-filter forward until
the hooks snaps in place. Make sure the
HEPA-filter is secured under the front edge
of the cover.
Dismount: Push downwards/backwards
on the HEPA-filters rear edge until it snaps
out.
d) Exhaust filter: Down to the left on
the exhaust filter holder there is a
indicator window, when the filter in the
indicator window looks dirty it is time to
change the filter. Remove the filter holder
by pressing the button on top of the
holder. Change the filter by grabbing the
filter flap and remove it from the filter
holder. Insert the new filter, make sure the
filter is inserted correctly. The longest side
down and the flap to the right. Reinsert
the filter holder and press it in place.
8 Hose connection
Push the hose coupling in to the hose
connection until it locks. Press the button
on the hose connection to remove the
hose.
9 Suction control
The suction control lets you regulate the
air flow through the hose. This is to
prevent the nozzle from sticking to the
surface vacuumed.
8
10 Power cord storage
Wind up the cord starting at the machine,
store it on the hook on the rear of the
machine.
11 Electronic level guard
When the container during wet pick-up
reaches maximum liquid level the machine
automatically stops. Reset the machine by
pressing the on/off button once before
emptying. The machine is equipped with
electrodes sensing the liquid level in the
container. If the machine automatically
stops before the container is full, the
electrodes probably needs cleaning. Simply
wipe them of with a damp cloth.
Always use a chemical defoamer
when picking-up water containing
foaming detergents. Use a defoamer
recommended by the detergents
manufacturer.
12 Electrical outlet
Under the lid there is a electrical out let
for power nozzel. Power is supplied to the
outlet when the machine is switched on.
NB!
Remove the plug from the socket before
performing service or maintenance.
IMPORTANT!
The machine is equipped with a specially
designed cable, which if damaged, must be
replaced by a cable of the same type.
These cables are avaible at authorized
service shops and must be installed by
trained personnel.
The machine is equipped with a thermal cut-
out to protect the motor and other vital
machine parts from overheating. Should the
machine cut out, you will have to wait at least
5-10 minutes before you try to start it again.
While you are waiting, switch the machine off
and unplug it, then check the hose, dust bag and
filters to be sure that nothing is blocking the
flow of air through the machine.
Note! it is neccessary to reset the machine by
pressing the on/off button, the machine will
not start again until this is done.

Publicidad

loading