Technical data for the BC 2.3
Magnification*
Working distance*
Viewing field
Distance between pupils
Dust-proof and water-resistant housing design.
*Values may differ for those with imperfect vision.
Use: These binocular magnifying glasses are only to be used by au-
thorized, trained personnel.
Purpose: These KaWe binocular magnifying eyeglasses are solely
intended to be used for magnification during medical examinations
and operations.
Unsuited use/contraindication of the products: Any use other
than that described here is not in accordance with the intended use
of the unit. The manufacturer is not liable for any resulting damages.
The user alone bears the risk.
Further instructions, maintenance, and storage: When used
and stored properly, this product will serve you reliably for many years.
Guarantee: When used properly and in accordance with the User's
Manual we guarantee this product for two years from the date of pur-
chase. Should you need further information or should your instrument
require repair, please contact your dealer.
Safety warning: 1. These magnifying eyeglasses may only
be used if they are in perfect condition. 2. Do not use the glasses if
they have any loose screws. 3. Caution – do not drop the magnifying
glasses – they may break! 4. In order to avoid eye damage, do not
look into the sun or any other bright light while wearing the magnify-
ing glasses!
Instructions
Storage and transportation: See Section F.
Cleaning preparation: No special requirements
Manual cleaning: The exterior surface of this product can be
cleaned with a damp, soft, lint-free cloth. Soap or other non-
aggressive agents may be used. The lenses of the binocular magni-
fying glasses can be carefully wiped clean with KaWe cleaning spray
as described in Section E.
Automatic cleaning: Automatic cleaning not possible/necessary.
2.3-times
Disinfection: The housing and ear pieces can be wiped clean with
a cloth that has been moistened with alcohol. Always dry all surfaces
340 mm / 13"
after cleaning them.
ca. 110 mm
50 to 74 mm
Maintenance: When used and cleaned properly, these binocular
magnifying eyeglasses are maintenance-free. The fastening screws
are only to be loosened by authorized professional technicians.
Inspection and functionality test: Check all moveable parts such
as joints. All devices: check for visible damage or wear.
Packaging: Packed individually in boxes.
Sterilisation: Sterilisation is neither necessary nor possible.
Storage: Store in a dry place between +5 and +60 °C, see Section F.
Disposal: This product is to be disposed of in accordance with local
regulations at a separate waste collection site/recycling centre.
Additional information: Follow this User's Manual. Should you
have any further questions, contact the manufacturer before using
this product.
Common accessories: Further information about these articles can
be found on our homepage at: www.kawemed.de.
Manufacturer: KaWe
Contacting the manufacturer: Write to or phone your dealer, or
dial +49-7141-68188-0.
Symbol key:
LOT
13
Manufacturer
Date of manufacture
Lot code
Heed the User's Manual