SOUND
Voice messages have been created to alert the
operator in case of problems or events that may
happen during the tightening operation.
The voice messages concern the following
topics:
- tightening out of tolerances
- calibration procedure
- preventive maintenance
- low battery
- hardware failure
- maintenance
When delivered, the function is disabled.
The sound function is disabled.
The sound function is enabled.
USING ICONS
Full battery
Low battery
This icon and the message "Low
battery" are displayed when the battery
is low and a voice message can be
heard when the sound function is
enabled. The tool cannot perform
anymore tightening.
● Load the battery by using the
Desoutter 36 V battery charger.
Pset password is locked
Pset password is unlocked
The amount of tightenings that can
be performed with a fully loaded
battery depends on the tool model
and application (from 100 to 1,000
tightenings with a 36 V 1.3 Ah battery
pack).
04/2014
04/2014
MAINTENANCE
HOW TO SET PASSWORDS
By default, both Pset and Maintenance
passwords are set to 1.
To set new passwords, current passwords must
be disabled and the green padlock displayed.
This function is set in the "Configuration" menu:
● Enter a figure from 0 to 999 for the Pset
password.
● Enter a figure from 0 to 999 for the
Maintenance password.
Setting the password at 0 will disable
all password protections.
● Save the new password as follows:
HOW TO CALIBRATE THE TOOL
In general, the calibration procedure is
recommended to compensate for any possible
drift of the tool torque or after each change of tool
element.
This function is set in the "Maintenance" menu.
● First enter the Maintenance password in the
"Configuration" menu.
● Insert a torque transducer in line with the tool
and connect it to any measuring unit from the
Desoutter range.
● Go to the "Maintenance" menu and press OK.
The tool is ready.
● Run a tightening Pset 5 times at max. torque
and with an angle above 180° (at low speed).
If more than 5 tightenings are required,
you can go on with 5 extra tightenings
by pressing the trigger.
● At the end, the average torque value is
displayed in white.
● On the red line below, enter the average
torque value measured by the measuring
unit (± 20 % vs the tool nominal torque are
allowed). Use the left/right buttons to increase
or decrease the value.
● Press OK and save your data.
The calibration is set to initial
production value each time you start a
new calibration process.
27 / 108
27 / 108
6159930390_05
Press OK: the password is
saved.
Press OK: the password is not
saved.