Códigos De Erro - Desoutter EAB15-900 Manual De Instrucciones

Ocultar thumbs Ver también para EAB15-900:
Tabla de contenido

Publicidad

Português
(Portuguese)
CÓDIGOS DE ERRO
Mensagem
004
Span failure
005
Offset failure
007
Motor too hot
008
Tool angle fault
009
Tool invalid param
012
Tool EEPROM error
018
Torque out of range !
026
Tool maint. alarm n1
027
Tool maint. alarm n2
029
The battery is empty
030
The battery is low
031
Battery error
032
Tool display error
033
Tool time error
034
Tool mem. err
035
Tool memory locked
036
Tool memory full
037
Tool trig err.
038
Tool logs
039
Tu config err
04/2014
04/2014
Solução
1- Span value from torque sensor is outside bounds.
2 -Try once again to start the tool with no mechanical constraints.
If the problem occurs again, contact your Desoutter representative
for support
1- Offset value from torque sensor is outside bounds.
2- Try once again to start the tool with no mechanical constraints.
If the problem occurs again, contact your Desoutter representative
for support.
1- Tool is locked because its maximum motor temperature has
been reached.
2- Tool will remain locked until the motor temperature comes back
to its normal value.
1- Problem detected with the tool angle sensor
2- The tool needs maintenance.
3- Contact your Desoutter representative for support
1- The tool memory cannot be read or is invalid.
2- The tool needs maintenance. If the problem occurs again,
contact your Desoutter representative for support.
1- The tool memory cannot be read or is invalid.
2- The tool needs maintenance. If the problem occurs again,
contact your Desoutter representative for support.
1- The target torque value is above the tool max. torque.
2- Check Pset settings with tool characteristics.
1- Tool maintenance tightening counter has been reached
1- Tool maintenance tightening counter has been reached
1- The battery is discharged. The tool cannot tighten.
2- Recharge the battery.
1- The battery is low.
2- Recharge the battery.
1- Abnormal battery voltage, the tool cannot tighten.
2- Recharge the battery. If the problem occurs again, replace the
battery.
1- Board display malfunction.
2- Contact your Desoutter representative for support.
1- The tool time is not set correctly. The tightening results will not
be time stamped.
2- Connect the tool to the controller to set date and time.
1- The tool memory does not work properly.
2- Contact your Desoutter representative for support.
1- The tool memory is locked to protect old data from rewriting.
2- Connect the tool to E-dock to retrieve old data.
1- The tool memory is full.
2- Connect the tool to the controller to empty the memory.
1- The tool trigger does not work properly.
2- Check and clean the trigger. If the problem occurs again,
contact your Desoutter representative for support.
1- Unexpected tool software exception
2- Log file has been generated by the tool
3-Contact your Desoutter representative for support
1- Tightening Unit settings are invalid
83 / 108
83 / 108
6159930390_05

Publicidad

Tabla de contenido
loading

Tabla de contenido