Mounting the hood body
• Before hooking up the hood body, adjust the 2 screws Vr lo-
cated on the hood body connection points so that they are at the
half way point.
• Hook the hood body to the mounted bracket.
• Adjust the screws Vr to level the hood body.
• Should the installer consider it necessary, the hood can be
fixed to the wall using two more screws with wall plugs, which
can be positioned from inside the hood canopy.
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
EN
Connections
Vr
ø 150
ø 120
9
1
18