– Max. permissible pressure (p max.): 12 MPa (120 bar)
– Max. water supply pressure (p in max.): 1 MPa (10 bar)
– Maximum water throughput (Q max.): 8.6 l/min (516 l/h)
– Max. suction lift: 0.5 m
– Max. water temperature in pressure mode (t in max):
40 °C
– Max. water temperature in suction mode: 20 °C
– Dimensions
– Length: 290 mm
– Width: 330 mm
– Height: 860 mm
– Length of high-pressure hose: 6 m
– Weight (m) with accessory attached: 9.7 kg
Version 220 V to 240 V / 50 Hz
– Fuse (characteristic "C" or "K"): 10 A
– Power consumption: 1.8 kW
– Electrical protection class: II
– Degree of electrical protection: IPX5 (protection from
water jets in any direction)
– Working pressure (p): 10 MPa (100 bar)
– Max. permissible pressure (p max.): 12 MPa (120 bar)
– Max. water supply pressure (p in max.): 1 MPa (10 bar)
– Maximum water throughput (Q max.): 8.3 l/min (500 l/h) to
8.6 l/min (516 l/h)
– Max. suction lift: 0.5 m
– Max. water temperature in pressure mode (t in max):
40 °C
– Max. water temperature in suction mode: 20 °C
– Dimensions
– Length: 290 mm
– Width: 330 mm
– Height: 860 mm
66
– Length of high-pressure hose: 6 m
– Weight (m) with accessory attached: 9.7 kg to 9.8 kg
Version 240 V / 50 Hz
– Fuse (characteristic "C" or "K"): 10 A
– Power consumption: 1.8 kW
– Electrical protection class: II
– Degree of electrical protection: IPX5 (protection from
water jets in any direction)
– Working pressure (p): 10 MPa (100 bar)
– Max. permissible pressure (p max.): 12 MPa (120 bar)
– Max. water supply pressure (p in max.): 1 MPa (10 bar)
– Maximum water throughput (Q max.): 8.3 l/min (500 l/h)
– Max. suction lift: 0.5 m
– Max. water temperature in pressure mode (t in max):
40 °C
– Max. water temperature in suction mode: 20 °C
– Dimensions
– Length: 290 mm
– Width: 330 mm
– Height: 860 mm
– Length of high-pressure hose: 6 m
– Weight (m) with accessory attached: 9.8 kg

19.2 Extension Cords

If an extension cord is used, the cross sectional area of its
conductors must meet the following minimum requirements
– depending on the line voltage and length of the extension
cord:
220 V to 240 V
– Cord length up to 20 m: AWG 15 / 1.5 mm²
– Cord length 20 m up to 50 m: AWG 13 / 2.5 mm²
19 Specifications