ERROR DISPLAY
KC-850E•KC-860E
DIGITAL
LAMP INDICATION
INDICATION
Flashing of the Clean Air &
Humidify Indicator Light.
Flashing of the Fan Speed
Indicator Light '
Flashing of the Clean Ion
Shower Indicator Light.
Flashing of the Clean Air Indi-
cator Light.
Flashing of the Fan Speed In-
dicator Light '
Flashing of the Fan Speed In-
dicator Light '
KC-840E
LAMP INDICATION
Flashing of the Clean Air &
Humidify Indicator Light.
Flashing of the Fan Speed
Indicator Light '
'.
Flashing of the Humidity Indi-
cator Light 'High' or 'Low'.
Flashing of the Clean Ion
Shower Indicator Light.
Flashing of the Clean Air Indi-
cator Light.
Flashing of the Fan Speed In-
dicator Light '
'.
Flashing of the Fan Speed In-
dicator Light '
'.
If error occurs again, contact the Sharp Service Centre.
ERROR DETAILS
Abnormal humidity fi lter
Abnormal fan motor
'.
Abnormal temperature-
humidity sensor
Problem in circuit board
'.
'.
ERROR DETAILS
Abnormal humidity fi lter
Abnormal fan motor
Abnormal temperature-
humidity sensor
Problem in circuit board
E-17
Verify if the Humidifying Filter,
Humidifying Tray and Water
Tank are properly installed and
then turn power ON again.
Turn power OFF to cancel the
error display, wait one minute,
and then turn power ON.
Unplug the unit, wait one
minute, and plug the unit in
again.
REMEDY
Verify if the Humidifying Filter,
Humidifying Tray and Water
Tank are properly installed and
then turn power ON again.
Turn power OFF to cancel the
error display, wait one minute,
and then turn power ON.
Unplug the unit, wait one
minute, and plug the unit in
again.
REMEDY

Publicidad