4.1. CALIBRATION PROCESS
4.1.1.
Activate your power meter (follow instructions in section
3.1. of the user manual) and complete the following calibration
process in less than two minutes.
4.1.2.
With the bike upright and level with the ground, place the
left crank in the 6 o'clock position as shown in the picture. Make
sure to complete the calibration process with the pedals already
installed; do not place any weight on them until the process has
finished.
4.1.3.
First calibration: follow the specific instructions for your
ANT+™ device to send the "CALIBRATION" signal.
4.1.4.
The device must show a value of 1000 or a message of
successful calibration. Turn the cranks
two turns at a moderate speed, returning again to a vertical
position with the left pedal down, making sure that the crank is
as perpendicular as possible to the ground for accurate angle
measurement.
4.1.5.
Second calibration: press again the "CALIBRATION" button.
The device then returns a calibration value between +/- 200.
There are some monitors in which a successful calibration
message will be shown. The second calibration has finished and
the power meter is ready to use.
For more information about the calibration process, user utilities
and training options, visit our website: www.power.rotorbike.com