General Warnings - Beninca MBE Manual De Instrucciones

Central de mando
Ocultar thumbs Ver también para MBE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
The electronic control unit MBE can be used to control 1 or 2 motors MB/MBE.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be physically detached, or adequately insulated by an additional
insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that settings of the Dip-switches are the required ones.
f)
The N.C. inputs which are not in use should be short-circuited.
Terminal No.
Function
1
ANT
2
SHIELD
3-8
SCA
4
P-P
5
STOP
6
FTC
7
+V
8-9
24 Vac
10-11
ELS
12-13-14
24-12-0
15-16-17
POWER-NT-FT
18-19
Power supply
20-21
LAMP
22-23-24
MB Motor
24-25-26
MBE Motor
#
Pedestrian
After adjusting the limit switches as shown in the actuator instruction manual, proceed as follows:
1) Cut-off power supply.
2) Manually release the wings, move them to approx. half-stroke and lock them again.
3) Reset power supply.
4) Send a step-by-step control signal by pressing the button or the remote control key.
5) The wings should start an opening movement. If this is not the case, invert the movement wires of the motor.
(22/23 for motor MB, and 25/26 for motor MBE).
6) Adjust Time, Operating Logic and Motor Power.
WARNING! This adjustment affects the safety of the automatic system.
Check that the thrust applied onto the wing complies with regulations in force.
A Faston (POWER) connector is provided on the power supply transformer which allows the power adjustment
of the motors on 3different levels. By moving the Faston (POWER) to 120, power is at minimum, by moving it to
190, power is at maximum.
WARNING! : As the MB/MBE actuator is not equipped with adjustable mechanical clutch, the POWER faston
must never be moved to 230V position.
6
MBE control unit

GENERAL WARNINGS

INPUT/OUTPUT FUNCTIONS
Description
Antenna Signal
Antenna Shield
Indicator lamp, Open gate
Input, N.O. step-by-step push-button
Input, N.C. STOP push-button
Input, safety devices connection, N.C. terminal (e.g. photocells)
Common to all control inputs.
Output, accessories power supply 24Vac/0,5 A max.
Electric lock connection, 12Vac/0,5A max.
Connection to transformer secondary winding
Connection to transformer primary winding
Input, 230Vac 50Hz (18-Phase/19-Neutral)
Output, flashing light connection, 230Vac 40W max.
Connection to MB motor (without control unit):
(22-movement/23-movement/24 com)
Connection to MBE motor (with control unit):
(24-com/25-mouvement/26 movement)
To use the pedestrian entrance, connect the normally open (N.O.) push-
button between +V (control common) and the little knob near terminal
STOP (see wire diagram).
To check connections:
To adjust the motor power

Publicidad

Tabla de contenido
loading

Tabla de contenido