General Warnings - Beninca SA.02 KIT Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
The electronic control unit SA.02 can be used to control 2 motors with a power not exceeding 350+350W.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be physically detached, or adequately insulated by an additional
insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that setting of the Dip-switches are the required ones.
Term. NO.
Function
1-2
Aerial
3
COM
4
PED
5
CH
6
AP
7
P-P
8
STOP
9
FTCC
10
FCA1
11
FCA2
12
FCC1
13
FCC2
14
FTCA
15
COM
16-17
SCA
18-19
ELS
20-21
24 VAC
22-23
Flashing light
24-25-26
Motor 2
27-28-29
Motor 1*
30-31
Power supply
32-33
CONT. AUX
34-36
LUCE CORT
37-38
2CH
*Should only one motor be in use, connect it to output Motor 1,
preset trimmer TRAC to minimum value, cut-off both FCA1 and
FCA2 for opening limit switches and FCC1 and FCC2 for closure, by
short-circuiting inputs as per wire diagram. Set Dip Bypass (DP2) No.
3-4-5-6 to OFF.
8
SA.02 Control Unit

GENERAL WARNINGS

INPUT/OUTPUT FUNCTIONS
Description
Aerial-receiver card connection (1-screen/2-signal).
Common to all control inputs.
Input, N.O. pedestrian push-button.
Activation is on motor M1 (27-28-29).
Input, N.O., Close button.
Input, N.O., Open button.
Input, N.O., Step-by-step button.
Input, N.C., STOP button.
Input, photocell which is activated only during closure.
Input, N.C., Motor 1 opening limit switch.
Input, N.C., Motor 2 opening limit switch.
Input, N.C., Motor 1 closing limit switch.
Input N.C., Motor 2 closing limit switch.
Input, photocell which is activated only during opening.
Common to all control inputs.
Connection, indicator light of open gate, 24 VAC/3W max.
Connection, electric lock, 12VAC/0.5A max.
Output, accessories power supply, 24VAC/1A max.
Output, flashing warning beacon connection, 230VAC 40W max.
Connection for motor 2 : (24-move/25-move/26-COM).
Delay in adjustable closure with Trimmer TRAC.
Connection to motor 1 : (27-move/28-move/29-COM).
Input, 230VAC 50Hz (keep to 30-Phase/31-Neutral).
Auxiliary voltage-free terminal, "Stairs light" (2A max.).
Output, "Courtesy light" (230VAC/50W max.).
Output, second radio channel of two-channel receiver.
N.O. voltage-free terminal.
���
10 11 12 13
����
����
����
����