The THIKS control unit can be used to control 1 single-phase, 230Vac motor or 1 three-phase, 400Vac motor with power not
exceeding 800W for single-phase motors and 2200W for three-phase motors.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be kept detached, or adequately insulated by an additional insulation of at least
1mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Normally Closed inputs which are not in use should be short-circuited.
f) The Power supply mains should be connected to an omnipolar switch with contact opening distance of 3mm, or higher distance.
Check that upstream the electric system is provided with an adequate differential switch and an overcurrent switch.
Terminal No. Function
1-2-3
Motor
4-5
Flashing light
5-6
AUX
Auxiliary capaci-
7-8
tor
9-10
Courtesy light
11-12
24Vac
13-14
SCA/PhotoTest
15
COM
16
SWO
17
SWC
18
PHOT 1
19
PHOT 2
20
PHOT 3
21
PHOT 4
22
STOP
23
OPEN
24
CLOSE
25
PED
26
Step-by-step
27
COM
28-29
DAS
30-31
Aerial
32-33
2
radio channel
nd
10
THINK Control Unit

GENERAL WARNINGS

INPUT/OUTPUT FUNCTIONS
THINK Control Unit
Description
Connection, 230Vac motor - single-phase:
1-Movement+capacitor/2-Common/3-Movement+capacitor
Connection, 400Vac motor - three-phase:
1-U/2-V/3-W
Check that the voltage selection jumper on terminals 36-37-38 is correctly positioned.
Connection of flashing light, 230Vac 40W max.
Connect a negative electric brake to this output.
WARNING: Output, 230Vac 0,5A max.
Free N.O. (Normally Open) contact (10A max) for pickup auxiliary capacitor.
See wire diagram. At each start-up the contact is closed for 1.5 sec.
Free N.O. contact (2A 150W) to control the Courtesy light which is timed according to the
TLS parameter.
Output, accessory power supply 24Vac/0,5A max
Output, 24Vac/0,5A max. This can be preset as open gate indicator light or as checked
devices power supply (PhotoTest) through the TSTP logic.
In the event of presetting as PhotoTest, please refer to the diagram "Connection of checked
safety devices"
Common for limit switches and photocells
Input, OPEN limit switch (N.C. contact)
Input, CLOSE limit switch (N.C. contact)
Input, Photocell 1 (N.C. contact). It can be disabled in the opening phase, see PHO1 logic.
Input, Photocell 2 (N.C. contact). It can be disabled in the opening phase, see PHO2 logic.
Input, Photocell 3 (N.C. contact). It can be disabled in the opening phase, see PHO3 logic.
Input, Photocell 4 (N.C. contact). It can be disabled in the opening phase, see PHO4 logic.
Input, STOP push-button (N.C. contact)
Input, OPEN push-button (N.O. contact).
Input, CLOSE push-button (N.O. contact)
Input, pedestrian push-button (N.O. contact)
Input, step-by-step (N.O. contact)
Common for all other control inputs.
Input, safety edge contact.
Resistive edge: closed " DAS" jumper.
Mechanical edge: open "DAS" jumper.
When the safety edge is activated, the gate movement stops. The gate movement is re-
versed for approximately 3 sec if the INVA logic is ON. If no safety edge is used: "DAS"
Jumper open, jumper between terminals 28-29.
Connection of the antenna to the receiver extractable board (30-signal/31-screen).
Output, 2
radio channel of the two-channel extractable receiver.
nd

Publicidad