Fitting the Hood Canopy
• Before hooking up the Hood Canopy, lock the 2
Screws Vr located at the Hood Canopy connection
points.
• Hook up the Hood Canopy to the Screws 12r taking
care to ensure that the Safety brackets 7.5, fixed to
the wall, enter the Side Housings provided.
• Tighten the support Screws 12r until they lock.
• Adjust Screws Vr to level the Hood Canopy.
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove possible charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Push fit connection 15 onto the hood body outlet.
• Insert the connection extension pieces laterally 14.1
in connection 15.
• Make sure that the outlet of the extension pieces 14.1
is horizontally and vertically aligned with the chim-
ney outlets. If this is not the case, adjust the position
by either reversing the connection extension pieces
14.1 and then reassemble as described previously.
• Ensure that the activated charcoal filters have been
inserted.
EN
Connections
Vr
12r
ø 150
15
7.5
ø 120
9
14.1
1
10