Examples (Stroke Counters) - Balluff BIP LD2-T017-01-EP Serie Manual De Instrucciones

Ocultar thumbs Ver también para BIP LD2-T017-01-EP Serie:
Tabla de contenido

Publicidad

BIP LD2-T017-01-EP _ _ / EP _ _ -S4
Inductive Positioning System
6
IO-Link interface (continued)
6.14

Examples (stroke counters)

6.14.1 Parameterizing a stroke counter via ISDU
The following must be set individually:
Position value (PW) for stroke counter 1 to 1000 μm:
0x2710
Set span (SP) for stroke counter 1 to 1000 μm: 0x03E8
Set stroke counter 1 mode to active: 0x01
Command sequence:
Index
Subindex
Value
0x020E
0x01
0x2710 Set PW stroke counter
0x020E
0x02
0x03E8 Set SP stroke counter
0x020E
0x03
0x01
Tab. 6-18: Command sequence
The above configuration can also be written completely as
a parameter set.
In this case all values are sent to Subindex 0.
Index
Subindex
Value
0x020E
0x00
0x2710
0x03E8
0x01
Tab. 6-19: Send values to Subindex 0
6.14.2 Move target to stroke counter position value
and save – system command
The position value of stroke counter range 2 should be set
per target to position 2000 μm.
Index
Subindex
Value
0x020D
0x00
0x02
Move target to 2000μm
0x0002
0x00
0xB6
Tab. 6-20: Set position value of stroke counter range 2 per target to
2000 μm
Set the span (SP) and mode for stroke
counter 2 also using parameterization via
ISDU.
Configure stroke counter 2 corresponding to Tab. 6-16.
www.balluff.com
Description
1 to 10000 μm
1 to 1000 μm
Set stroke counter 1
mode to enabled
Description
Set PW stroke counter
1 to 10000 μm; set SP
stroke counter 1 to
1000 μm; set stroke
counter 1 mode to
disabled
Description
Select stroke counter
channel 2
Teach stroke counter
position
6.14.3 Reset stroke counter configuration to default
values – system command
Reset the configuration of stroke counter 3 to the default
values:
Index
Subindex
Value
0x020D
0x00
0x03
0x0002
0x00
0xB7
Tab. 6-21: Reset stroke counter 3 to the default values
Description
Select stroke counter
channel 3
Reset stroke counter
configuration
english
25

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bip ld2-t017-01-ep -s4 serieBip001yBip ld2-t017-01-ep00,5-s4

Tabla de contenido