Remove The Pump From The Melter; Special Reassembly Instructions - Nordson ProBlue P4 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

D‐8
SP Pump Diagnostics and Repair

Remove the Pump from the Melter

Part 1024496_05
1. Relieve system pressure. Refer to Relieving System Pressure in
Section 5.
See Figure D‐1.
2. Isolate the pump from the manifold by rotating the isolation valve handle
to its full vertical position (valve closed).
3. Remove the three M8 pump‐mounting bolts from the front of the pump
body.
4. Rotate the top of the pump slightly toward the front of the melter while
pulling the pump away from the manifold.
NOTE: The face of the pump body contains two M6 threaded holes.
Bolts can be threaded into these holes to gain leverage when removing
the pump.
5. Remove the air line from the back of the pump.
6. Lift the pump clear of the melter, and place it in a bench vise or other
suitable mount.
Pump‐to‐manifold
O‐rings
P/N 1019515
P/N 942111
Cross‐over tube O‐rings
P/N 940133 (2)
PTFE
back‐up ring
P/N 954013

Special Reassembly Instructions

S
Before reinstalling the pump, lubricate the O‐rings on the cross‐over
tubes and the two O‐rings between the pump and the manifold.
Check/Repair
Inspect for nicks,
gouging, or swelling
Inspect for nicks,
gouging, or swelling
Apply Parker lubricant
during reassembly
Apply Parker lubricant
during reassembly