Electric Installation - WEG DBW-01 Guía De Instalación, Configuración Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Figure 3: Installation procedures for the
DBW-01 and DBW-02 on surface
223
(8.78)
150
(5.905)
36.5 (1.437)
Figure 5: Cutout dimensions in air duct - mm(inch)
- For more details consult the manual of CFW-09

2. ELECTRIC INSTALLATION

For installing the DBW module, follow the guidelines bellow:
Step 1
With the frequency inverter not energized, remove the CFW-09 frontal cover;
Step 2
Remove the DBW braking module frontal cover;
Step 3
Supply the fan of the braking module with the suitable supply voltage
(110 V or 20 V) through terminals 1 and 2 of connector X7
2
has a requires a current of about 0.14A;
Step 4
Connect the +UD grounding of the braking module to the +UD terminal of
the inverter,
according to figure 8;
Step 5
Connect the -UD grounding of the braking module to the -UD terminal of the
inverter,
according to figure 8;
Step 6
Connect the interconnection cable to connector XC3
of the braking module
fastened to the metallic support in the side of the CFW-09 control board, see figure 8;
Step 7
Connect the braking resistor and the thermal relay in series, between terminals
+UD and BR
Step 8
The terminals 3 and 4 of the terminal block X7 are the NC-contact of a thermostat
that must be installed for the thermal protection of the braking module. This
protection must be installed external to the braking module (see Figure 7); in this
example, the relay is connected to DI3 (terminal 3 and 9 of connector XC1 in the
CC9 board) and the parameter P265 is programmed as Without External Error
(P265=4).
Table 2:
Type
DBW-01 165
DBW-01 240
DBW-01 300
DBW-02 210
DBW-02 300
DBW-02 380
7.2
.
Attach the other cable end to the Db9 connector, which is
,
according to figure 8.
Air Flow
Figure 4: DBW-01 and DBW-02 Positioning
Mechanical Data of the DBW-01 and DBW-02
Fastening Screw
M6
(figure 6)
.
Degree of
Weigth Kg
Protection
14.2
13.8
13.4
IP20
14.2
13.8
13.4
(see figure 7). The fan
on the CRG4 board
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dbw-02

Tabla de contenido