Installation, Setup and Operation Guide
Dynamic Braking Module DBW-01 and DBW-02
I. SAFETY NOTICES
ATTENTION!
- Be sure that the AC input power is disconnected before making any terminal
connection.
- Many power components may be charged with high voltages, even after the mains
supply has been disconnected. Wait at least 10 minutes before touching any electrical.
II. GENERAL INFORMATION
This guide provides information for the correct installation, configuration and operation
of Dynamic Braking Module
Table 1: Models of Dynamic Braking Module DBW-01 and DBW-02 in the CFW-09.
Supply Voltage
Inverter
[V]
Types
180A
211A
240A
312A
380-480V
361A
450A
515A
600A
100A/107A
127A/147A
179A/211A
225A/247A
500-690V /
660-690V
259A/315A
305A/343A
340A/418A
428A/472A
(*) See item 3. Technical Specifications.
III. PACKAGE CONTENT
Model of Dynamic Braking Module DBW-01 and DBW-02
Quantity
Entrada de señales de encoder
1
1
DBW-01 and DBW-02 in the CFW-09
Max. Braking
Braking
Current
Module
DBW010165D21802SZ
DBW010240D21802SZ
DBW010240D21802SZ
DBW010300D21802SZ
DBW010300D21802SZ
DBW010300D21802SZ
DBW010300D21802SZ
DBW010300D21802SZ
DBW020210D5069SZ
DBW020210D5069SZ
DBW020210D5069SZ
DBW020210D5069SZ
DBW020300D5069SZ
DBW020300D5069SZ
DBW020380D5069SZ
DBW020380D5069SZ
Dynamic Braking Module DBW
Interconnection cable
RMS Braking
Minimum
(1)
(2)
Current
Resistor
A
A
200
165
320
240
320
240
400
300
400
300
400
300
400
300
400
300
250
210
250
210
250
210
250
210
400
300
400
300
500
380
500
380
Description
.
Power Wiring
(3)
(BR, -UD, +UD)
2
mm (AWG)
70 (2/0)
4
120 (250MCM)
2.5
120 (250MCM)
2.5
2X50 (2X1/0)
2
2X50 (2X1/0)
2
2X50 (2X1/0)
2
2X50 (2X1/0)
2
2X50 (2X1/0)
2
120 (250MCM)
4.8
120 (250MCM)
4.8
120 (250MCM)
4.8
120 (250MCM)
4.8
2X50 (2X1/0)
3
2X50 (2X1/0)
3
2X120 (2X250MCM)
2.5
2X120 (2X250MCM)
2.5
1