DIAG FUNCTION
- 13.5V
DIAG+ FUNCTION
- 12V to 14.8V (for 12V battery)
- 24V to 29.6V (for 24V battery)
- 6V to 7.4V (for 6V battery)
Voltage adjustment (only in Diag+ mode)
After selected the battery voltage, it is possible to adjust the voltage by 0.1V step according to manufacturer's specifications.
DIAG+ MODE CONFIGURATION
DIAG+
12V
U=13.5V
DIAG+
12V
U=13.5V
DIAG+
24V
U=27.2V
Precaution: Before using the Diag Mode. If the screen displays a current greater than 10A, it indicates the battery
is discharged. The device will start charging automatically Check all electrical consumers are switched off on the
vehicle. Wait until the current falls below 10A and then re-launch the diagnostic.
SHOWROOM MODE
On a stationary vehicle, the GYSFLASH supplies up to 30A (and 15A in 24V) to test high-energy consumers (engine fan, window
regulator, electronic suspension, etc...) by supplying a steady voltage adjustable:
- 12V to 14.8V (for 12V battery)
- 24V to 29.6V (for 24V battery)
- 6V to 7.4V (for 6V battery)
Voltage adjustment:
After selected the battery voltage, it is possible to adjust the voltage by 0.1V step according to manufacturer's specifications.
SHOWROOM MODE CONFIGURATION
SHOWROOM
12V
U=13.5V
SHOWROOM
12V
U=13.5V
SHOWROOM
24V
U=27.2V
Start without battery (not recommended)
Possibility to stop the alarm beep by pressing the START/STOP key for 3 seconds.
The indictation « no battery » displays for 1 second before supplying the power.
Warning: polarity reversal can damage the vehicle electronics.
Precaution
Before using the Showroom Mode. If the screen displays a current higher than 10A, it indicates the battery is discharged. The device
will start charging automatically Check all electrical consumers are switched off on the vehicle. Wait until the current falls below 10A
and then re-start the showroom support.
GYSFLASH 30-24 HF
6V
12V
24V
6.0V
12.0V
24.0V
6.1V
12.1V
24.1V
...
...
...
7.4V
14.8V
29.6V
6V
12V
24V
6.0V
12.0V
24.0V
6.1V
12.1V
24.1V
...
...
...
7.4V
14.8V
29.6V
Start up :
• Connect the clamps : red to the (+) and black to
the (-) of the battery.
• Push the START/STOP key to start the mode.
• During use the current consumed and the instan-
taneous voltage are displayed.
STARTING DIAG
DIAG
U=13.5V
Connection with battery :
• Connect the clamps : red to the (+) and black
to the (-) of the battery.
• Push the START/STOP key to start the mode.
• During use the current consumed and the ins-
tantaneous voltage are displayed.
STARTING SHOWROOM
SHOWROOM
13.5V
EN
DIAG
U=13.5V
I=12A
SHOWROOM
U=13.5V
I=12A
13