Troubleshooting - GYS GYSFLASH 30-24 HF Manual De Instrucciones

Ocultar thumbs Ver también para GYSFLASH 30-24 HF:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
1
Testing battery elements in short-circuit
2
Recovering damaged elements from an extended deep discharge
3
Sulphated battery test
4
Sulphated battery recovery
5
Checking the battery recovery
6
Battery charged to 80%
7
Battery charged to 90%
8
Battery cells refresh
9
Cells break time
10
Levelling out battery cells
11
Battery charged to 100% (charge resumption after 48h)
PROTECTIONS
This device is protected against short-circuits and polarity inversions. It has an anti-spark feature which prevents sparks whilst
connecting the Gysflash to the battery. The Gysflash will not deliver current if there is no battery detected (no voltage in the clamps).
The charger is fitted with an internal 40A fuse (ref. 054646), to protect against misuse.

TROUBLESHOOTING

TROUBLESHOOTING
Screen flashing :
1
« #error (+)<-->(-) »
+ alarm beep
Screen flashing :
2
« #error U>Umax »
+ alarm beep
Screen flashing :
3
« #battery error »
+ alarm beep
Screen flashing :
4
« >30A »
+ alarm beep
The GYSFLASH delivers a high cur-
5
rent (greater than 10A) before the
diagnostic tool has been activated.
Displays for 1s :
« no battery »
6
+ alarm beep
The device is locked in Showroom
7
mode
Screen displays :
8
« #error temp(°C) »
+ alarm beep
Screen displays :
9
« #error IHM »
+ alarm beep
Screen displays :
« #error fuse »
10
+ alarm beep
The device does not display
11
anything
18
GYSFLASH 30-24 HF
CAUSES
The polarity has been reversed on the clamps
Battery voltage too high
Battery in short-circuit or damaged
Battery not connected or clamps in short-circuit
Error on the battery voltage selection
Consumption exceeds the output of the charger
Several consumers are active on the vehicle
Battery discharged
«Showroom mode is working on « no battery »
Lock Showroom active
Faulty fan
Sun exposure
Electronic fault
Mishandling
Input fuse faulty
Faulty electrical network
REMEDIES
Connect the red clamp to the (+) and the black clamp to the (-) of the battery.
Charger not suitable.
Change the battery.
Check clamps connection.
Charger not suitable.
Turn off electrical consumers to reduce power demand
GYSFLASH works to specification. Turn off consumers to check the battery is not
too discharged (see cause n°2).
Battery deeply discharged, the GYSFLASH delivers current to charge it. Wait
until the output current is below 10A to start the diagnostic.
Showroom without battery : GYSFLASH operating normally.
To deactivate the «no battery» function, press the «START/STOP» key, and then
press the «START/STOP» key again to start the Showroom mode with battery.
GYSFLASH works to specification.
See configuration menu to deactivate the function.
Contact your distributor.
Do not leave the device exposed to sunlight.
Leave the device ON until the fault disappears. (The alarm beep can be stoppe-
dPossibility to stop the alarm beep by pressing the START/STOP key).
Contact your distributor.
Internal fuse must be changed by a qualified person
(ref. 054646 : 40A).
Input fuse must be changed by a qualified person
(temporised fuse 6.3A 5x20, ref. 054578).
Check the voltage of the electrical network is between 180V and 260V.