GYS GYSFLASH 30-24 HF Manual De Instrucciones página 16

Ocultar thumbs Ver también para GYSFLASH 30-24 HF:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
• Reset Memory (code 1-9-6-4) :
This menu is intented to factory reset the charger settings by
entering the code above. Any personal parameters are deleted.
ADVANCED MENU
This menu controls the advanced parameters of the charger.
To move from one parameter to another push the Select key :
Activation «Power Supply» > Activation «Expert Curve» (> Adjustment of the «Expert Curve» parameters)
SELECT
• POWER SUPPLY mode activation :
To activate the POWER SUPPLY mode, select «ADVANCED MENU | Power
Supply : ON». Now this mode will be accessible from the mode list
• «EXPERT» curve activation :
To activate the «EXPERT» curve, select «ADVANCED MENU | expert curve
: ON». Now this curve will be available in the charging curves list from the
CHARGE mode.
• Parameter adjustment of the «EXPERT» curve :
If the charging curve «EXPERT» is activated, the charging curve parame-
ters can be adjusted (type IU
- Unominal : battery nominal voltage (6V, 12V or 24V)
- Ucharge : adjustable voltage from 6.0V to 30.0V.
- Urecovery : recovery voltage adjustable up to 30V. If the value «OFF»
is selected the recovery function is inactive.
- Ufloating : floating voltage adjustable depending on the Unominal va-
lue selected If the value «OFF» is selected the floating function is inactive.
- T recovery : maximum time for cells recovery in short-circuit, adjus-
table from 1h to 12h.
- T refresh : Time for the refreshing phase adjustable from 1h to 12h. If
the value «OFF» is selected, the refresh function is not activated.
aAttention :
Warning: When charging on the vehicle, the refresh function
must not be activated (T recovery: OFF).
A voltage «Urecovery» too high might damage the electronics of
the vehicle. We advise NOT to set-up this setting above 15V.
To save and validate the new settings, select «ADVANCED MENU» | save? Yes»
Push the «MODE» key to exit the «Configuration» menu.
16
GYSFLASH 30-24 HF
I
U) :
0
0
RESET MEMORY
0
RESET MEMORY
1
...
Code:
0000
9
RESET MEMORY
Change the
Code NOK
code number
Error Code
Code OK
(1964)
Display 1s
RESET MEMORY
Code OK
Yes
RESET MEMORY
Reset all ?
No
ADVANCED MENU
ADVANCED MENU
Power Supply: OFF
ADVANCED MENU
Expert Curve:
OFF
OFF
ON
EXPERT CURVE
Unominal:
12V
EXPERT CURVE
Ucharge:
14.3V
EXPERT CURVE
Urecovery:
OFF
EXPERT CURVE
U oating:
OFF
EXPERT CURVE
T recovery*:
5h
EXPERT CURVE
T refresh:
5h
ADVANCED MENU
Save?
No
RETURN
EN
ON
OFF
ON
OFF
6V
12V
24V
6.0V
12.0V
24.0V
6.1V
12.1V
24.1V
...
...
...
8.0V
16.0V
30.0V
OFF
OFF
OFF
Uch
Uch
Uch
...
...
...
29.9V
29.9V
29.9V
30.0V
30.0V
30.0V
OFF
OFF
OFF
6.0V
12.0V
24.0V
6.1V
12.1V
24.1V
...
...
...
Uch
Uch
Uch
1h
2h
*accessible only if
...
Urecovery = OFF
12h
OFF
1h
2h
...
12h
Yes
No

Publicidad

Tabla de contenido
loading

Tabla de contenido