Step 6: Electrical Requirements, Connection & Grounding
A 3- or 4-conductor
supply may be connected
to the
terminal
block.
3-WIRE LEAD CONNECTION
1.
Remove
upper nuts only from the terminal
block
studs.
Do
not
remove
nuts
which
secure
range
internal
wiring
leads.
2.
Secure
the neutral,
grounded
wire of the supply
circuit, to the center stud of the terminal
block with
nut. (See Fig. 11).
3.
Secure the L1 (black) and L2 (red) power leads to
the outside
terminal
block studs (brass colored)
with nuts.
4.
Tighten
nuts securely.
4-WIRE
CONNECTION
.
.
.
Remove
upper nuts only from the terminal
block
studs.
Do
not
remove
lower
nuts
which
secure
range
internal
wiring
leads.
Remove
ground
strap screw
and bend the strap
up as shown in Fig. 12
Secure
the neutral
wire to the center stud of the
terminal
block with nut.
4.
Secure the L1 (black) and L2 (red) power leads to
the outside
terminal
studs
(brass
colored)
with
nuts.
.
Secure the bare copper ground lead to the range
chassis
using the ground screw previously
used
for the ground
strap.
Be sure
that neutral
and
ground terminals
do not touch.
6.
Tighten
all connections
securely.
FIG. 10
FIG. 11
Conductor Securement
_ _
_[
UpperNut
_X._X
(___.,
Cupped Washer
__"
SF_PtPlYaWih; r
3 Wire Connection
L1 Black
FIG. 12 Ground Strap
L2 Red
Neutral White
o
Bend Ground Strap Up
FIG. 13
Secure Neutral Wire
Ground Wire