S8910U3000
CORRESPONDANCES
DES BORNES
S8910U
6
TERRE (BRÛLEUR)
24 V (TERRE)
VANNE (TERRE)
24V
VANNE
L2
L1
HSI
HSI
CAPTEUR
CONTRÔLEUR
GAZ COMBINÉ
1
1
ALIMENTATION. PLACER SI NÉCESSAIRE UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES.
VEILLER À NE PAS INVERSER L1 ET L2.
2
EMPLACEMENT DU LIMITEUR AUXILIAIRE.
3
L'ÉLECTRODE DE DÉTECTION EST PRÉSENTE POUR LE MODÈLE À DÉTECTION À DISTANCE HS780. VOIR LE TABLEAU 2.
4
LORSQUE HS780 EST UN MODÈLE À DÉTECTION À DISTANCE, RETIRER LE CONNECTEUR RAPIDE DE CAVALIER DU S8910U.
COUPER LE FIL CAVALIER AU NIVEAU DE LA CARTE DE CIRCUIT ET LE JETER. BRANCHER LE FIL DE L'ÉLECTRODE DE FLAMME AU CAPTEUR.
VOIR LE TABLEAU 2.
5
COUPER LE CONNECTEUR RAPIDE DE 1/4 PO DU FIL ET LE REMPLACER PAR LE CONNECTEUR RAPIDE 3/16 PO (FOURNI).
6
UTILISER L'ADAPTATEUR DE TERRE VERT FOURNI POUR RELIER LA TERRE DU S8910U (BRÛLEUR) AU CHÂSSIS DE L'APPAREIL.
Fig. 3. Raccordement typique lorsque le modèle S8910U remplace le modèle Robertshaw HS780.
34-00008EFS—01
CONTRÔLEUR D'ALLUMAGE PAR INCANDESCENCE S8910U
HS780
TR (CLIP DE TERRE)
WARNING
TERRE
Explosion Hazard. Can cause
serious injury or death.
Disconnect power before ser-
—
vicing. This device can mal-
function if it gets wet. Never
try to use a device that has
TH
been wet -- replace it.
VANNE
L2
L1
ALL.
ALL.
RS
6
TERRE DU
BRÛLEUR
MV
MV
Golden Valley, MN 55422
Assembled in Mexico
S8910U Hot Surface Ignition
Selection Tab
Input Voltages = 120 & 24 VAC, 60 Hz
Trial count
ON
Control Status
HSI = 120V, 5A max.
OFF
= 1 try (default)
Valve = 24V, 2A max.
Device damaged- Red
Total 24V Load = 0.4 + valve load
ON
Trial count
U.S. Patent 8,085,521
OFF
= 3 tries
Ignition lockout
ON
Trial for ign. period
Normal operation Green Steady
Prepurge Time = 32 Sec.
OFF
= 4 seconds (default)
Weak flame signal Green Blink
Igniter Warm Up Time = See Inst. Sh. 34-00008
Trial for ign. period
ON
See Instruction Sheet 34-00008
Ignition Trial Time - See Selection Tab
OFF
= 7 seconds
for additional states
Number of Trials - See Selection Tab
1
2
3
4
Between Trial Time - 96 Sec.
120 VAC
See
NOTE: ALWAYS apply
NEUTRAL
LED
this control as instructed
States
in Instruction Sheet
34-00008
SYSTEM SETUP
5
THERMOSTAT
2
OU CONTRÔLEUR
12
LED States
Color Pattern
Steady
replace control
®
Red
Blink
C
US
AUTO
IGNITION
SYSTEMS
ANSI Z21.20
32304204-001 Rev. A
120 VAC
See
HOT
Instructions
for
CAPTEUR
Single/Dual
Rod
DE FLAMME
Applications
4 4
4
4
ALLUMEUR PAR
INCANDESCENCE
LIMITEUR
L1
(SOUS TENSION)
L2
3
1
MF8529