Heat
Excessively high temperatures can damage controls. Make
sure the maximum ambient temperature at the control does not
exceed the rating of the control. If the appliance operates at
very high temperatures, use insulation, shielding, and air
circulation, as necessary, to protect the controls. Proper
insulation or shielding should be provided by the appliance
manufacturer; verify proper air circulation is maintained when
the appliance is installed.
INSTALLATION
When Installing this Ignition System...
1. Read these instructions carefully. Failure to follow them
could damage the components or cause a hazardous
condition.
2. Check Tables 1, 2, and 3 to confirm that the S8910U is a
direct replacement for the existing module.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out component and
appliance operation as provided in these instructions.
WARNING
FIRE OR EXPLOSION HAZARD.
CAN CAUSE PROPERTY DAMAGE, SEVERE
INJURY, OR DEATH.
1. If the ignition module gets wet, it can malfunction,
leading to accumulation of explosive gas.
— Never install where water can flood, drip or
condense on the module.
— Never use a module that has been wet.
Replace it.
2. Liquefied petroleum (LP) gas is heavier than air
and can not vent upward naturally.
— Do not light pilot or operate electric switches,
lights or appliances until you are sure the
appliance area is free of gas.
3. Do not attempt to disassemble or clean the module.
Improper reassembly and cleaning can cause
unreliable operation.
34-00008EFS—01
CAUTION
1. Disconnect the power supply before beginning
wiring to prevent electrical shock or equipment
damage.
2. If a new gas control is to be installed, turn off the
gas supply before starting the installation. Conduct
a Gas Leak Test according to the gas control
manufacturer instructions after the gas control is
installed.
3. If a module must be mounted where it can be
exposed to moisture or water, provide a suitable
waterproof enclosure.
4. Using the wire labels provided, label all wires
before disconnecting. Wiring errors can cause
improper appliance operation and create
dangerous conditions such as bypassing safety
features.
Perform Preinstallation Safety Inspection
A preinstallation safety check of the appliance and venting
system must be done before the replacement module is
installed. If a condition is detected that could result in unsafe
operation, shut off the appliance and advise the owner of the
unsafe condition. Correct any potentially unsafe condition
before proceeding with the installation.
Remove Old Module
Disconnect power supply before doing any work on the unit.
Disconnect and tag the wires from the old module using the
wire labels provided. Remove the old module from its mounting
location.
Mount New Ignition Module
Mount the S8910U Module in the same location as the old
module. Protect the module from exposure to water, moisture,
corrosive chemicals and excessive dust and grease. Assure
that ambient temperature at the module is within the range
listed in the Application section.
Mount the module with the terminals down to protect from
dripping water and dust. The module can also be mounted with
terminals on either side. Do not mount with the terminals
pointing up. Refer to Fig. 1 for mounting recommendations.
When it is necessary to drill new mounting holes, use the
S8910U as a template to mark the mounting hole pattern. Drill
new holes as required. Fasten securely with four No. 6-32
machine or No. 8 sheet metal screws.