Table 6: Operation failures
Problem
The unit tends to shut
down
The unit is not delivering
power
The power supplied is not
constant
The battery charger does
not supply voltage
Cause
Requested power higher than
2,5 kW
Air filter blocked
Oil level too high
The inverter is broken
Malfunction in the pump power
supply
Injectors dirty or faulty
The power cables are
disconnected or they do not
provide a continuous supply
The inverter is broken
Requested power higher than
2,5 kW
Air filter blocked
The power cables are
disconnected or they do not
provide a continuous supply
The inverter is broken
Malfunction in the pump power
supply
Injectors dirty or faulty
Damaged battery charger fuse
- 41 -
Remedy
Decrease the required voltage
load
Clean the air filter
Check the oil level, and remove
excess oil if necessary (See "Do
not mix oils with different cha-
racteristics or from different
manufacturers.")
Contact the service department
Contact the service department
Contact the service department
Contact the service department
Contact the service department
Decrease the required voltage
load
Clean the air filter
Contact the service department
Contact the service department
Contact the service department
Contact the service department
Replace fuse (See "Replace-
ment of fuses")
Use, maintenance and installation instructions
TEC 30D EV
GB