5
Intervals (as required in Germany)
The maintenance intervals are recommended by
MSA AUER. Applicable national regulations must
be observed. If required, the local conditions
during use must be considered for the work to be
performed. In case of doubt, the local MSA repre-
sentative should be consulted and the applicable
national regulations be checked.
Work to
be
Before After
performed Use
Use
1)
Cleaning
and
X
Disinfection
Visual-,
Function-
and
X
Leak Test
Exhalation
Valve disc
replace-
ment
Speech
diaphragm
replace-
ment
Check by
user
X
(Tightness)
1) Facepieces which are regularly used should be
cleaned and disinfected as often as required. They
should be cleaned as soon as possible after each
use because perspiration or saliva that dries unto
the valves could cause malfunctions. The mask
must be disinfected at least before it is used by
another person.
2) For airtight packaged facepieces.
The manufacturing date of the full face mask is
marked behind the harness clasp on the lateral
flap of the faceblank. Example: Manufacturing
date April 2001
The manufacturing date of the exhalation valve
disc is marked on its outside,
Example: Manufacturing date 2001.
Intervals
Semi- Two
Four
Six
annu-
Years
Years
Years
ally
X
X 2)
X
X
6
Storage
The mask should be stored in a carrier.
In order to prevent damage or distortion of the
mask, no additional objects must be stored in the
carrier.
Storage must be in clean, dry and normal climate,
i.e. cool, dry and free from hazardous material,
protected against light and radiant heat. It is
recommended to observe German Standard DIN
7716: 1982, and ISO 2230: 1973.
7
Accessories
7.1

Carrying Strap

For carrying full face mask and suspending it in
front of the chest.
8

Ordering Information

Description
ADVANTAGE 3211 (S) small *)
ADVANTAGE 3221 (M) medium *)
ADVANTAGE 3231 (L) large *)
X
ADVANTAGE 3212 (S) small **)
ADVANTAGE 3222 (M) medium **)
ADVANTAGE 3232 (L) large **)
Nosecup M/L
(for Full Face Masks ADVANTAGE
3221, 3231, 3222 and 3232)
Nosecup S (for Full Face Mask
ADVANTAGE 3211, 3212)
Lens, Twin (with Gaskets, Dual Port)
Lens Ring, Kit
Inhalation Valve (20 pcs)
Exhalation Valve (10 pcs)
Gasket, Dual Port (10 pcs)
Connector Twin (with O-Ring and Clip) 100 32 106
Head Harness ADVANTAGE
Head Harness ADVANTAGE, Si
Cover for Connector
O-Ring for Connector (5 pcs)
Carrying Strap
Carrier ADVANTAGE
Prescription Spectacles
ADVANTAGE
MSA AUER Disinfectant 90, 2 litres
MSA AUER Disinfectant 90, 6 litres
MSA AUER Leak Test Kit
Adapters ADVANTAGE (for leak test)
**) with head harness ADVANTAGE
(textile neck strap)
**) with head harness ADVANTAGE,
Si (silicone neck strap)
Part No.
100 27 727
100 27 726
100 27 728
100 42 732
100 42 733
100 42 734
100 32 104
100 32 103
100 32 112
100 32 114
D2056 714
100 32 110
100 32 111
100 32 102
100 42 663
100 32 107
100 32 108
100 32 100
100 26 179
according to type
D2055 765
D2055 766
D6063 705
100 17 835
100 32 102
100 42 663
9

Publicidad

Tabla de contenido
loading

Tabla de contenido