5
Authorization
This section covers the RFID authorization feature of
EVLunic B+ and Pro S. For the description of the authorization function of EVLunic Pro M, see
the "Configuration Manual".
EVLunic B+ and Pro S can optionally be equipped (see Fehler! Verweisquelle konnte nicht g
efunden werden. Overview of variants) with the following authorization functions:
■
Authorization via RFID card
■
Authorization via key switch
Also, with the enable input X1, it is possible to authorize the charging via ex- ternal components
(e.g., house control, ...). For more information, see the "Installation Manual".
5.1
Displays and signals
During authorization, the charging station can display different light patterns on the LED bar and
emit acoustic signals.
LED bar
Display
Flashing green
(every 3 seconds)
Flashing blue
(every 3 seconds)
Orange (S4)
Acoustic signals
Signal
Single tone
Rising tone sequence
Falling tone sequence
5.2
Authorization via RFID
By default, a charging procedure can be started without authorization. In or- der to use the
authorization via RFID, RFID cards need to be taught-in.
A maximum of 20 RFID cards can be taught into a charging station. An RFID master card must
first be taught-in for this. Using this master card, additional RFID slave cards can subsequently
be taught-in.
Operating instructions V 1.00 Document: V 1.00 / Document No.: 105728 │ Date 28.05.2018
Description
Authorization done correctly. / No authorization required.
The charging station is waiting for authorization to enable a charging
process. Authorization necessary, either by key switch, RFID card or via the
enable input X1.
The teach-in of an RFID slave card must be confirmed by hold- ing the RFID
master card in front again.
Description
Authorization by key is done correctly. / RFID card has been read.
RFID card has been accepted.
RFID card has been rejected (no authorization).
Authorization