4 | Structure and function
*Examples of climate classes:
Climate class
Ambient tem-
(class) accord-
perature [°C]
ing to ISO
23953-2
3
3.3
Use as intended
The appliance is intended for the display of packaged,
deep frozen food products or access to them by cus-
tomers.
For more information, see [see } Chapter 1.4]
4
Structure and function
The appliance is a compact device ready to plug in.
The appliance is supplied ready for use and has its
own control unit.
The appliance is pre-programmed ex works.
The appliance contains one or more hermetically
sealed refrigerant circuits whose components are per-
manently and technically tightly connected to each
other.
The design of the individual appliance models may
vary.
Appliance can be combined with another Commercial
refrigeration appliance.
1
Fig. 1: KINLEY (1), Commercial refrigeration appliance (2)
The appliance is equipped with display shelves.
Optional accessories
– Mesh baskets
Display shelves/mesh baskets can be expanded, re-
duced or repositioned.
The appliance is equipped with stacking marks
[see } Chapter 10.1].
The appliance is equipped with doors.
Door self-closing mechanism
The door closes by itself as of a specific angle.
The waste heat generated in the appliance is trans-
ferred to the ambient air via a heat exchanger.
The appliance defrosts automatically at regular inter-
vals [see } Chapter 4.1].
The appliance is equipped with stickers.
– Power rating plate [see } Chapter 3.2.1]
– Symbol
The stickers are located at the top right inside the ap-
pliance.
42 / 788
Relative humid-
ity [%]
25
60
1
2
Inspection tasks
– Presence of the stickers
– Function of the self-closing mechanism on the
doors
Responsibility
– Operating personnel
Frequency
See Maintenance [see } Chapter 11]
If any parts are missing or in the event of a malfunc-
tion, contact the maintenance service immediately
[see } Chapter 12.4].
4.1
Automatic defrosting
The appliance features automatic defrosting.
The frequency, duration, and time of defrosting are
preset.
Defrosting frequency
– 1 time per day (or according to customer require-
ments)
Defrost time
– Up to 60 min
During automatic defrosting, the following display
screen and symbols appear on the display
[see } Chapter 5].
Controller
Display
AHT (Secop GP)
Carel
AHT (WURM)
The water released during defrosting is routed from
the interior of the unit into heated condensation water
trays where it evaporates.
CAUTION
Leakage of condensation water.
Slipping hazard.
§ Check for puddles in front of and under
the appliance.
§ Promptly remove leaking condensation
water.
§ Contact the maintenance service immedi-
ately [see } Chapter 12.4].
During the defrosting process, an increase in the tem-
perature can occur on the internal temperature dis-
play.
5
Control and display
elements
5.1
Temperature display
The temperature of the appliance is set at the factory
to ensure compliance with the M-package temperature
class specified by the manufacturer
[see } Chapter 3.2].
AHT Cooling Systems GmbH | en
Symbol
376840_1_0920