4 | Structure and function

Parameter
Value
Neutral white
4000 K
Custom deviations possible.
More information: Maintenance services
[see } Chapter 12.4]
Subject to technical changes.
3.2.1

Rating plate and serial number

Observe the information on the rating plate.
The rating plate is a sticker located at the top right in-
side the appliance.

Information on rating plate

– Appliance name and type
– Serial number
– Climate class*
– Rated voltage and frequency
– Rate current and consumption
– Refrigerant and quantity used
– Net content
– Date of manufacture
– and further technical data
*Examples of climate classes:
Climate class
Ambient tem-
(class) accord-
perature [°C]
ing to ISO
23953-2
3
3.3

Use as intended

The appliance is intended for the display of packaged,
refrigerated food products (specifically meat products)
or access to them by customers.
For more information, see [see } Chapter 2.2]
4
Structure and function
The appliance is a compact device ready to plug in.
The appliance is pre-programmed ex works.
The appliance contains one or more hermetically
sealed refrigerant circuits whose components are per-
manently and technically tightly connected to each
other.
The design of the individual appliance models may
vary.
The waste heat generated in the appliance is trans-
ferred to the ambient air via a heat exchanger.
The appliance defrosts automatically at regular inter-
vals [see } Chapter 4.1].
The appliance is equipped with glass sliding doors.
The appliance is equipped with a soft-close mechan-
ism, enabling slow and secure closing of the doors.
Function of the soft-close mechanism
34 / 500
Relative humid-
ity [%]
25
60
– The door must be braked shortly before its end po-
sition.
– The door must close slowly and completely.
CAUTION
Soft-close mechanism does not brake
the door.
Hands (body parts) may be trapped.
§ Check the function of the soft-close mech-
anism.
§ In the event of damage/malfunction,
promptly contact the maintenance service
[see } Chapter 12.4].
NOTICE
Property damage due to incorrect ambient
conditions.
§ Make sure the doors are closed.
§ In the event of damage/malfunction, promptly con-
tact the maintenance service [see } Chapter 12.4].
Display shelves are installed on delivery.
Changes to the number and position of display
shelves by agreement with the manufacturer only.
The appliance is equipped with stacking marks
[see } Chapter 10.1].
4.1

Automatic defrosting

The appliance features automatic defrosting.
The frequency, duration, and time of defrosting are
preset.
Defrosting frequency
– 3 times per day (or customer-specific)
Display
During automatic defrosting, the following display
screen and symbols appear on the display
[see } Chapter 5].
Display
The water produced on defrosting is routed from the
interior of the appliance where it evaporates.
CAUTION
Leakage of condensation water.
Slipping hazard.
§ Check for puddles in front of and under
the appliance.
§ Promptly remove leaking condensation
water.
§ Contact the maintenance service immedi-
ately [see } Chapter 12.4].
If required, semi-automatic defrosting can be used
[see } Chapter 5.2.1].
AHT Cooling Systems GmbH | en