Kohler K-6228 Guía De Instalación Y Cuidado página 12

Griferías de montaje a la pared para lavabo
Ocultar thumbs Ver también para K-6228:
Tabla de contenido

Publicidad

4.
Adjust the Valve - Right Handle
CAUTION: Risk of property damage. The water supply must be shut off before
performing these steps.
Shut off the water supply.
Remove the plaster guard/retaining ring tool.
Position a bucket at the spout outlet, then open the valve handle to relieve water
pressure. Leave the handle open.
Loosen the threaded retaining ring using the plaster guard/retaining ring tool
until the valve body disengages from the mixer valve.
CAUTION: Risk of property damage. At the maximum valve body extension, a
detent will be encountered. To avoid leakage, do not extend the valve beyond this
detent. If the valve body needs to be extended further, installation of the deep
rough-in valve body kit (1107027) is required. If the valve needs to be recessed
further, installation of the shallow rough-in valve body kit (1107026) is required.
Using a straight edge, adjust and hold the valve body flush with the finished wall.
NOTE: A screwdriver inserted through the holes in the plaster guard/retaining ring
tool can serve as a handle.
With the valve body flush with the finished wall, retighten the retaining ring with
the plaster guard/retaining ring tool.
Close the valve handle.
Turn on the water supply and check that the valve is functioning properly.
1095311-2-G
Threaded Retaining Ring
Anneau de retenue fileté
Anillo de retención roscado
Plaster Guard/
Retaining Ring Tool
Renfort en plâtre/
Outil d'anneau de retenue
Herramienta para
protector de yeso/
anillo de retención
12
Kohler Co.

Publicidad

Tabla de contenido
loading

Tabla de contenido