1. GENERAL

This booklet briefly outlines where and how to install the
air conditioning system. Please read over the entire set of
instructions for the indoor and outdoor units and make sure all
accessory parts listed are with the system before beginning.

1-1. Tools Required for Installation (not supplied)

1.
Flathead screwdriver
2.
Phillips head screwdriver
3.
Knife or wire stripper
4.
Tape measure
5.
Carpenter's level
6.
Sabre saw or key hole saw
7.
Hacksaw
8.
Core bits
9.
Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for deburring)

1-2. Accessories Supplied with Unit

See Tables 1-1 to 1-6.
Table
1-1
4-Way Air Discharge Semi-Concealed X Type
1-2
4-Way Air Discharge Semi-Concealed XM Type
1-3
Wall-Mounted
1-4
Ceiling-Mounted
1-5
Concealed-Duct U Type
1-6
Concealed-Duct US Type

1-3. Type of Copper Tube and Insulation Material

If you wish to purchase these materials separately from a local
source, you will need:
1.
Deoxidized annealed copper tube for refrigerant tubing.
2.
Foamed polyethylene insulation for copper tubes as
required to precise length of tubing. Wall thickness of the
insulation should be not less than 8 mm.
3.
Use insulated copper wire for field wiring. Wire size varies
with the total length of wiring. Refer to 5. ELECTRICAL
WIRING for details.
CAUTION
Check local electrical codes and regulations before
obtaining wire. Also, check any specified instructions or
limitations.

1-4. Additional Materials Required for Installation

1.
Refrigeration (armored) tape
2.
Insulated staples or clamps for connecting wire (See your
local codes.)
3.
Putty
4.
Refrigeration tubing lubricant
5.
Clamps or saddles to secure refrigerant tubing
6.
Scale for weighing
Type
Table 1-1 (4-Way Air Discharge Semi-Concealed X Type)
Part Name
Figure
Full-scale
installation
diagram
Flare insulator
Insulating
tape
Hose band
Packing
Drain
insulator
Drain hose
Washer
Screw
Table 1-2 (4-Way Air Discharge Semi-Concealed XM Type)
Name
Washer
Flare insulation
Insulation tie
Vinyl tie
Drain hose
insulation
Full-scale
installation
diagram
Washer head
screw
Drain hose
Hose band
Use 9.52 mm for suspension bolts.
Field supply for suspension bolts and nuts.
Table 1-3 (Wall-Mounted K Type)
Part Name
Figure
Plastic cover
Truss-head
Phillips
Tapping
4 × 16 mm
screw
Insulator
7
Q'ty
Remarks
1
Printed on container box
2
For gas and liquid tubes
For gas and liquid tube
(White)
2
flare nuts
1
For securing drain hose
1
For drain joint
1
For drain joint
1
For securing drain hose
8
For suspension bolts
For full-scale installation
4
diagram
Figure
Q'ty
Remarks
For temporarily
8
suspending indoor
unit from ceiling
T3
2
For gas / liquid tube
T5
set
connection
For gas / liquid tube /
2
flare nut connection
For flare / drain
8
insulating
connection
For drain tube
T10
1
connection
Printed on
1
container box
For full-scale
4
installation diagram
For unit & PVC tube
1
connection
L140
For drain hose
2
connection
Q'ty
Remarks
For improved tubing
1
appearance
10 For fixing the rear panel
For insulating flare nut
1
(254 type only)