INSTALLATION
To operate a good installation of the gear motor
EPO follow these instructions:
Make sure that the leaves of the gate are perfectly
horizontal.
Install temporary the supports "S1" and "S2" on
the operator.
Install the support "S1" using the pivot "P1",
making attention to the mounting way (11 mm
toward the high, 13 toward the low,
using the supplied screws and self-Lubrificate
bushes
(fig.
1).
Install the support "S2" loosing the screw "V" and
introduce the pivot "P" in its base "F" and fix the
security screw "V"
(fig.
Start the operator and move the pivot "P" axle up
700 mm from the back axle of the pivot "P1"
3).
Decide the maximum opening of the leaf, from 90°
to 120°, and consult the table
Decide the vertical position you want to install the
operator.
Make sure that the operator is perfectly horizontal
and weld temporary the support "S1" to the
column of the gate, in the position as per table in
fig. 3, and the support "S2" to the leaf.
If the column is not in iron material, weld the
support "S1" on the support "S3", and fix it on the
column by special unsupplied screws
Release the gear motors like explained in the par.
"Emergency or manual manoeuvre", and carry
out a manual opening and closing to check the
correct position of the gear motor.
Dismantle the gear motor from the supports "S1"
and "S2".
Fix definitively the supports "S1" and "S2" by a
very good welding.
Install the gear motor on the supports repeating
the above instructions.
Make the circuitry like in the control panel manual
and install the obligatory safety devices.
Teach the people intended for the use of the
automation about the controls, safety devices,
emergency manoeuvre and dangerousness
deriving from the utilize of the automation.
Compile the technical booklet and fulfil the
eventual obligations deriving from the regulations
in force.
EPO/OPEN VERSION
Version with water proof electrical limit switch's
opening/closing, already installed and connected
by DASPI.
Install under the back pivot "P1" the pivot
supporting the cams "PC", fixing it by supplied
screw "V1"
(fig.
5). Insert the limit switch cams
"CM1.CM2" on the pivot "PC".
Adjust the cam "CM1" (up) carring out with a
manual manoeuvre the leaf in the maximum
wished opening position, turn the cam till to hear
the click of the limit switch.
fig.
1), and
2).
(fig.
3).
(Fig.
4).
(fig.
4).
Adjust the cam "CM2" (down) carring out with a
manual manoeuvre the leaf in closing position and
turn the cam till to hear the click of the limit switch.
Carry out an automatic manoeuvre to check the
correct position of the cams "CM1-CM2" and
correct if is necessary.
Fix the screws "V2" to block the cams.
EPO/FIN-MECC VERSION
Version with mechanical limit switch supplied
installed on the endless screw by DASPI.
Loose the grubs "G1-G2" screwed on stops "FM1-
FM2"
(fig.
6).
(fig.
Put with a manual manoeuvre the leaf in closing
position and turn the stop "FM1" till it touch the
female screw "C", so fix the grub "G1".
Put with a manual manoeuvre the leaf in the
maximum wished opening position and turn the
stop "FM2" till it touch the female screw "C", so fix
the grub "G1".
Carry out an automatic manoeuvre to check the
correct position of the stops "FM1-FM2" and
correct if is necessary.
We garantize the correct functioning of
EPO/OPEN and EPO/FIN-MECC versions only and
exclusively if provided by DASPI
combined with the original control panel.
EMERGENCY OR MANUAL MANOEUVRE
You have to do the emergency or manual
manoeuvre or during the installation, or only if the
automation does not work properly or if there is
not power supply.
CUT OFF THE POWER SUPPLY.
Open the plug on the handle "LS" cover and insert
the supplied key "CH"
Turn the key "CH" clockwise and putting the
handle in vertical position opens the gate
manually.
In order to re-establish the normal functioning of
the automation, you have to put again the handle
"LS" in horizontal position and turn the key "CH"
anticlockwise, so take away the key and reinstall
the plug on the handle.
Place the key "CH" in a safety place known
exclusively from the people intended for the use of
the automation.
Switch on the power supply, pay attention that
there's nobody where the gate is moving.
and only if
(fig.
7).