4. Technical specifications
Blue Power Charger IP65
Input voltage range
Efficiency
Standby power consumption
Minimum battery voltage
Charge voltage 'absorption'
Charge voltage 'float'
Charge voltage 'storage'
Charge current
Charge current in low current mode
Temperature compensation
(lead-acid batteries only)
Can be used as power supply
Back current drain
Protection
Operating temp. range
Humidity (non condensing)
Battery-connection
230 V AC-connection
Protection category
Weight
Dimensions (h x w x d)
Safety
Emission
Immunity
10
12 V 5/7/10/15 A
180-265 VAC
94%
Starts charging from down to 0 V
Normal: 14,4 V
High: 14,7 V
Li-ion: 14,2 V
Normal: 13,8 V
High: 13,8 V
Li-ion: 13,5 V
Normal: 13,2 V
High: 13,2 V
Li-ion: 13,5 V
5 / 7 / 10 / 15 A
2 / 2 / 3 / 4 A
16 mV/°C
0,7 Ah/month (1 mA)
Reverse polarity
Over temperature
-20 to +50°C (full rated output up to 30°C)
Max 95 %
ENCLOSURE
Black and red cable of 1,5 meter
Cable of 1,5 meter with
CEE 7/7, BS 1363 plug (UK) or AS/NZS 3112 plug
IP65 (splash and dust proof)
0,9 kg
12/7: 47x95x190mm
0ther: 60x105x190mm
STANDARDS
EN 60335-1, EN 60335-2-29
EN 55014-1, EN 61000-6-3, EN 61000-3-2
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
24 V 5/8 A
95%
0,5 W
Normal: 28,8 V
High: 29,4 V
Li-ion: 28,4 V
Normal: 27,6 V
High: 27,6 V
Li-ion: 27,0 V
Normal: 26,4 V
High: 26,4 V
Li-ion: 27,0 V
5 / 8 A
2 / 3 A
32 mV/°C
Yes
Output short circuit
0,9 kg
24/5: 47x95x190mm
24/8: 60x105x190mm