SPECIFICATIONS
• E24 Motor Card Requirements
Power Requirements
•
Power In
o
24.0 VDC nominal @ 3 A maximum
Limited to 1.5 A when DIP switch 4 is Off
Normal operation from 22.0 – 28.0 VDC
Will allow operation above 28.0 VDC but control will get hotter.
Will allow operation below 22.0 VDC but full speed will be
unattainable.
o
29.0 + 0.2 VDC over-voltage detection (unit will cease normal
operation)
o
19.0 + 0.2 VDC under-voltage detection (unit will cease normal
operation)
o
Polarity protection is provided
Note that the control's ground does not attach to the metal
chassis; doing so assures a solid ground but then if the power
supply is reversed it's positive output
o
fuse to only be replaced with a 5A Slo-Blo Littlefuse 0454005 or
equivalent.
•
NPN/PNP Selectable Inputs
(see page 14) PNP is recommended.
o
NPN Input Signal Levels (When switch 2 is Off)
Active when pulled down below 2.0 VDC
Need to be able to sink 3 mA
o
PNP Input Signal Levels (When switch 2 is ON)
Active when pulled up above 18.0 VDC
Need to be able to source 3 mA
o
Two input signals (See page 14)
motor Run
motor Reverse
Analog Speed Input
•
Allow the speed to be controlled from a single point
Voltage range: 0-10 VDC
minimum impedence presented to input: 5K
• RBE24EZ Connections
Figure 10A
6 1/2
– can be either an NPN or PNP input
ZONE LENGTH
Longitud de Zona
•
PNP Output
o
Signal Levels
Sources current when active
maximum current for this unprotected output is 50mA.
A 150Ω series resistor helps the PNP output limit current draw
for most situations; voltage out is thus lower as current draw
increases.
Voltage dependent on input power and current draw.
o
One output signal
motor Running
Environmental Requirements
•
Temperature
o
The unit shall operate within specified limits over the range of -20 to
40 °C (-4 to 120 °f).
o
The unit can be stored in the range of -40 to 85 °C (-40 to 185 °f).
Humidity
•
o
The unit shall operate within specified limits in relative humidity in
the range of 20 to 90% (non-condensing).
o
The unit can be stored in the range of 5 to 95% (non-condensing).
Safety – Unintended Use Considerations
Installer
•
o
This product is intended for installation by qualified personnel
only; although of relatively low voltage there are dangerous levels
of current controlled on the board that are not protected from
misplaced fingers.
Note that the cover makes it difficult to touch any power other
than the fuse.
A tool will be required to tweak the pot or move the DIP
switches; a plastic-tip screwdriver is recommended.
o
Should the on-board fuse require replacement always use only that
detailed in this specification.
User
•
o
Product shall be located away from the user such that touching of
the control is not possible.
o
Should the on-board fuse require replacement always use only that
detailed in this spec.
ZONE CONTROLLER
UNIDRIVE MOTOR CONTROL
Controlador de Zona
Tarjeta del Motor Unidrive
Wiring Harness W/Drops
Arnés de Cableado Con
Conexiones
10