Electrical Integration Into The Elevator System - Kübler PSU01 Instrucciones De Utilizacion

Sistema de copia de eje
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• In case of excessive capacitively coupled interference in the inspection circuit (see maintenance
instructions), they must be correctly eliminated by the customer using power resistors or capacitors.
• No users with a high interference level, such as frequency converters, solenoid valves, contactors,
etc. should be connected to the voltage supply of the electronics (PSU Evaluation Unit, Ants LES01,
control). Otherwise, a suitable voltage filter must be provided.

5.3 Electrical integration into the elevator system

This chapter describes PSU01 in the overall system and explains the electrical integration into the lift
system.
The figure below displays the correct integration of the PSU Evaluation Unit with Ants LES01 in the
elevator system.
emergency stop area
landing door contacts
lock contacts
car door contact
EN - page 16 (R60953.0009 3)
position-data CAN-OPEN
X2
X3
4
5
6
7
8
9
10 11 12
F2A
X5
X6
19
18
22
23 24
main contactor
activation
main contactors
LIFTCONTROL
safety chain
ground
Wiring Diagram PSU01
CE0408TÜV-A-AT XXX
Ants LES01 is connected to Kübler Position Supervisor Unit
via CAN interface.
position/SSI (optional)
X4
13
14 15 16 17
Position Supervisor Unit
supply input
X1
X8
20 21
1
2
3
28
29
inspection
AC
AC
F2A
X7
26
27

Publicidad

Tabla de contenido
loading

Productos relacionados para Kübler PSU01

Tabla de contenido