Important Remarks - V2 VEO-RFE Serie Manual De Instrucciones

Motorreductor tubular ø 35 mm con final de carrera electrónico, encoder y receptor de radio incorporado
Ocultar thumbs Ver también para VEO-RFE Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
EU DECLARATION OF CONFORMITY
AND DECLARATION OF
INCORPORATION OF PARTLY
COMPLETED MACHINE
Declaration in accordance with Directives: 2014/35/UE (LVD);
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B
The manufacturer V2 S.p.A., headquarters in
Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy
Under its sole responsibility hereby declares that:
the partly completed machinery model(s):
VEO-RFE6-230V, VEO-RFE10-230V
VEO-RFE6-120V, VEO-RFE10-120V
Description: electromechanical actuator for awnings and
rolling shutters
- is intended to be installed on awnings and rolling shutters
to create a machine according to the provisions of the
Directive 2006/42/EC. The machinery must not be put into
service until the final machinery into which it has to be
incorporated has been declared in conformity with the
provisions of the Directive 2006/42/EC (annex II-A).
- is compliant with the applicable essential safety requirements
of the following Directives:
Machinery Directive 2006/42/EC (annex I, chapter 1)
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
Radio Directive 2014/53/EU
Directive ROHS2 2011/65/CE
The relevant technical documentation is available at the national
authorities' request after justifiable request to:
V2 S.p.A., Corso Principi di Piemonte 65,
12035, Racconigi (CN), Italy
The person empowered to draw up the declaration and to provide
the technical documentation:
Giuseppe Pezzetto
Legal representative of V2 S.p.A.
Racconigi, 1st June 2015
m

IMPORTANT REMARKS

Please read the instruction carefully before installation
Follow all instructions, since incorrect installation can lead to
severe injury
The installation must be done by a technician following the
safety norms in force
Only apply to authorized personnel to replace the feeding
cable of the motor
Do not pierce nor insert screws in the whole length of the
motor
Avoid any contact of the motor with liquids
Avoid to crush or knock over the motor
Possible tampering or wrong connections are not covered by
guarantee
If a manual release is provided, the actuating member is to be
installed at a height less than 1,8m
Before installing the drive, remove any unnecessary cords and
disable any equipment not needed for powered operation.
For installation for awnings, a horizontal distance of at least
0,4 m is to be maintained between the fully unrolled driven
part and any permanent object
The power supply cable should not be exposed to sunlight or
rain directly
Assure that all accessories have been fixed so that the motor
works without any mechanical problem. The loading weight
should be matched with the output power of the motor
Electrical connection must be done by professional technicians
to operate in conformity with the rules
Do not allow children to play with fixed controls
Keeps remote controls away from children
Frequently examine the installation for imbalance and sings of
wear or damage to cables and springs
Do not use if repair or adjustment is necessary
Moving parts of the drive must be installed higher than 2.5 m
above the floor or other level that could provide access to it
The actuating member of a biased-off switch is to be located
within direct sight of the driven part but away from moving
parts. It is to be installed at a minimum height of 1.5 m
Fixed controls have to be installed visibly
The appliance can not be used in outside
- 18 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Veo-rfe6-230vVeo-rfe10-230vVeo-rfe6-120vVeo-rfe10-120v

Tabla de contenido